{"id":4416,"date":"2020-08-26T09:20:23","date_gmt":"2020-08-26T09:20:23","guid":{"rendered":"https:\/\/clinlabint.3wstaging.nl\/elisa-assay-for-25-hydroxyvitamin-d\/"},"modified":"2021-01-08T11:29:18","modified_gmt":"2021-01-08T11:29:18","slug":"elisa-assay-for-25-hydroxyvitamin-d","status":"publish","type":"post","link":"https:\/\/clinlabint.com\/elisa-assay-for-25-hydroxyvitamin-d\/","title":{"rendered":"ELISA assay for 25-Hydroxyvitamin D"},"content":{"rendered":"

Based on recently developed monoclonal antibodies, an innovative easy-to-use ELISA assay with all-in-one (AIO) technology for the measurement of 25-Hydroxyvitamin D TOTAL (D2 and D3) has been launched. These antibodies have already been successfully used in the 25-Hydroxyvitamin D TOTAL RIA assay. Specifically designed to be used manually as well as on open automated systems, this ELISA uses a pre-treatment step that is executed directly in the assay well, and has a total assay time of less than 4 hours. The assay has been validated on the Stratec GEMINI open ELISA automated analyser (Stratec Biomedical GMBH, Germany) and a validated protocol is available to all Stratec GEMINI users. Offering major advantages with respect to ease-of-use to laboratory technicians (AIO technology), this assay is ideal for medium-sized and smaller labs with a throuput of 10 to 80 samples per day. Higher sample numbers can easily be run on any open automated ELISA platform. Assays for 25-Hydroxyvitamin D3 specific RIA , 25-Hydroxyvitamin D Total RIA and 1,25-Dihydroxyvitamin D RIA, as well as monoclonal antibodies against 25 Hydroxyvitamin D (total), are available for use by other assay developers.
\n
\nSupplier:<\/strong> DIAsource ImmunoAssays
\nWebsite:<\/strong> <\/a><\/p>\n

Mail the supplier<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"

Based on recently developed monoclonal antibodies, an innovative easy-to-use ELISA assay with all-in-one (AIO) technology for the measurement of 25-Hydroxyvitamin D TOTAL (D2 and D3) has been launched. These antibodies have already been successfully used in the 25-Hydroxyvitamin D TOTAL RIA assay. Specifically designed to be used manually as well as on open automated systems, […]<\/p>\n","protected":false},"author":2,"featured_media":10118,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[39],"tags":[],"_links":{"self":[{"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/posts\/4416"}],"collection":[{"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/comments?post=4416"}],"version-history":[{"count":0,"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/posts\/4416\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/media\/10118"}],"wp:attachment":[{"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/media?parent=4416"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/categories?post=4416"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/clinlabint.com\/wp-json\/wp\/v2\/tags?post=4416"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}