Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
November 2025
The leading international magazine for Clinical laboratory Equipment for everyone in the Vitro diagnostics
Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.
Accept settingsHide notification onlyCookie settingsWe may ask you to place cookies on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience and to customise your relationship with our website.
Click on the different sections for more information. You can also change some of your preferences. Please note that blocking some types of cookies may affect your experience on our websites and the services we can provide.
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to provide the website, refusing them will affect the functioning of our site. You can always block or delete cookies by changing your browser settings and block all cookies on this website forcibly. But this will always ask you to accept/refuse cookies when you visit our site again.
We fully respect if you want to refuse cookies, but to avoid asking you each time again to kindly allow us to store a cookie for that purpose. You are always free to unsubscribe or other cookies to get a better experience. If you refuse cookies, we will delete all cookies set in our domain.
We provide you with a list of cookies stored on your computer in our domain, so that you can check what we have stored. For security reasons, we cannot display or modify cookies from other domains. You can check these in your browser's security settings.
.These cookies collect information that is used in aggregate form to help us understand how our website is used or how effective our marketing campaigns are, or to help us customise our website and application for you to improve your experience.
If you do not want us to track your visit to our site, you can disable this in your browser here:
.
We also use various external services such as Google Webfonts, Google Maps and external video providers. Since these providers may collect personal data such as your IP address, you can block them here. Please note that this may significantly reduce the functionality and appearance of our site. Changes will only be effective once you reload the page
Google Webfont Settings:
Google Maps Settings:
Google reCaptcha settings:
Vimeo and Youtube videos embedding:
.U kunt meer lezen over onze cookies en privacy-instellingen op onze Privacybeleid-pagina.
Privacy policy
Human lecithin-cholesterol acyltransferase ELISA
, /in Product News /by 3wmediaLecithin-cholesterol acyltransferase (LCAT) is a 58 kDa glycoprotein responsible for cholesterol esterification in plasma. LCAT has an important physiological role in the maturation of nascent, discoidal high density lipoproteins (HDL) into mature, spherical HDL, through the generation of a cholesteryl ester (CE)-enriched core. Plasma and tissue accumulation of free cholesterol and nascent HDL particles have been observed in familial LCAT-defi cient subjects. The enzyme has also been implicated in the reverse cholesterol transport pathway. Plasma LCAT activity is elevated in metabolic syndrome and may be a marker of subclinical atherosclerosis. The Human LCAT ELISA kit is suitable for serum, plasma (EDTA, citrate) and cerebrospinal fl uids samples. Th e 96 well-microtitre plate format can be used with standard ELISA equipment.
Read more
Urine analysis
, /in Product News /by 3wmediaAvailable in two versions, the Urilyzer 100 and the Urilyzer 100 Pro offer a number of benefits. At first usage, a start-up wizard leads the user through the soft ware for individual settings. The measurement will be started automatically by the strip detection technology. The colour touch-screen improves data entry and allows manual input of colour, turbidity and comments. The user is provided with a high level of customization with flexible testing and reporting options. The intelligent database-driven data management provides multiple filter options. The Pro version provides enhanced operator management and connectivity capabilities for compliance management and data capture. Additionally, the analyser offers a sediment recommendation for defined parameters, automated QC analysis with QC test reminders, and LOT code documentation. For security, the Pro version allows the allocation of diff erent security levels to individual users with different rights.
Read more
High-specification microscope slides
, /in Product News /by 3wmediaDiamondWhite glass microscope slides are produced from hand-selected white glass sheets. White glass provides better optical properties than standard microscope slide glass – the slide is so clear that one sees the sample not the slide. The surface of the slide has low sodium oxide content and provides a better surface for long term storage.
Read more
Low level testosterone measurement
, /in Product News /by 3wmediaWith a simple blood test, the ARCHITECT 2nd Generation Testosterone Assay can accurately measure the wide range of testosterone levels seen in a number of different patient populations and clinical settings. Testosterone assays play an important role in the diagnosis and management of many medical conditions in men, women, and children. However, many currently available testosterone assays are not sensitive enough to measure low levels of testosterone. This system allows reliable and reproducible assessment of testosterone in patients suspected to have low circulating testosterone levels, attributes which can be beneficial for patients and their doctors as well as for the laboratory. The device provides consistent and accurate testing of testosterone levels across a wide range of concentrations and fulfils the need for a rapid, sensitive and fully automated testosterone assay. The assay is a chemiluminescent microparticle immunoassay for the quantitative determination of testosterone in human serum and plasma. Measurements of testosterone are used in the diagnosis and treatment of disorders involving 1) the male sex hormones (androgens) including primary and secondary hypogonadism, delayed or precocious puberty, and impotence in males; and 2) in females, hirsutism (excessive hair) and virilization (masculization) due to tumours, polycystic ovaries, and androgenital syndromes. Health care providers can now confidently measure testosterone levels and use this information to improve treatment decisions for their patients.
Read more
Personal lab sterilizer
, /in Product News /by 3wmediaA compact, easy-to-use personal lab sterilizer, the CoolCLAVE uses ozone gas to clean laboratory tools. It is effective in sterilizing and deodorizing lightly contaminated pipettes, pipette tips, gloves, plates, small instruments, and even personal items such as keys and glasses. Items are simply placed inside the sterilizer and the START button pressed. The anti-microbial properties of ozone provide a powerful sanitizing effect that is capable of killing more than 98% of most pathogenic organisms (bacteria, fungus, virus, etc.) in just 8 minutes while also eliminating the odours produced by these organisms, thus providing an additional benefi cial deodorizing effect. The sanitizer is very safe and efficient, operating without using any harsh chemicals, harmful UV rays or heat, and does not damage any surfaces or leave any chemical residues behind. The ozone is able to penetrate into cavities or crevices that are unreachable by other methods, like ethanol spray or UV lamps, so research tools or personal items are more thoroughly and safely cleaned. Th e device is inexpensive to run and is highly reliable, requiring minimal maintenance.
Read more
Pneumonia diagnostics
, /in Product News /by 3wmediaThe Unyvero System is a versatile hardware platform for the detection of a broad panel of bacteria and antibiotic resistances from a single sample in one run. It processes a disposable cartridge providing the necessary reagents to complete the analysis from sample to report. The Unyvero P50 Pneumonia Cartridge is the first cartridge developed by Curetis and focuses on pathogen as well as antibiotic resistance testing for pneumonia. Each cartridge handles one patient sample and simultaneously analyses 39 DNA targets. Results are available within less than 4 hours. This technology offers the fast, precise and automated diagnosis of infectious disease agents and their antibiotic resistances, contributing to improved clinical outcomes and limiting the risk of increasing antibiotic resistance.
Read more
Field evaluations demonstrate accuracy of Mindray’s BC-6800 hematology analyser
, /in Product News /by 3wmediaThe BC-6800 is the latest addition in the Mindray hematology analyser portfolio and was developed innovatively using field evaluations. The company was actually ready with the prototype BC-6800 system in January 2010 and started system stability tests at that time.. Based on extensive testing of the prototype system and subsystems, many improvements were incorporated and the product was ready for shipment by September 2011. But, in order to ensure that the analyser was able to fulfil endusers’ needs, Mindray decided to undertake pre-launch evaluations and selected Turkey, the USA, Czech Republic and China as the evaluation sites. After receiving positive feedback about the BC-6800 performance from all the sites, it was decided to proceed with the launch in November 2011. Even after that time, evaluations were continued in different countries such as Italy, Spain, France and Australia so as to ensure that the BC-6800 matches local endusers’ needs.
During the R&D phase, the company performed stability tests on every subsystem. For example, each autoloader was tested for over 1,000,000 times and again with the integrated BC-6800 system, which itself has been tested for a cumulative total of over 600,000 times.
During the pre-launch evaluations at the Duzen laboratory group, one of the largest chain of labs in Turkey, the BC-6800 was compared to Abbott’s CELL DYN Sapphire and showed very good correlation of results. Additionally, the lab selected some leukemia samples, which were tested on both the BC-6800 and a flow cytometer as well as examined under the microscope. The BC-6800 displayed good flagging efficiency on these samples.
At pre-launch evaluations in two US labs, i.e. the Metropolitan hospital and the Eccolab group based in Miami, Florida, the BC-6800 was compared to the Sysmex XE-2100 and microscopic examination. The results showed good correlation between the BC-6800, the XE-2100 and microscopic examination. The users also found the reliability of the instrument very impressive, since there were no breakdowns during the whole time of the evaluation.
In the Czech Republic, the BC-6800 was installed at the Svitavy hospital last October for pre-launch evaluation. The senior laboratory physician was very happy with the instrument concluding that “the performance of the BC-6800 is better than the competitor’s, especially on Monocyte and Neutrophil results”.
During the pre-launch phase, Mindray also tested the efficiency of two ‘first in its class’ features available on BC-6800 for malaria screening i.e. ‘Infected RBC?’ flag and ‘InR % & #’, a parameter for research use only (RUO). The results were presented in a poster at the International Society for Laboratory Hematology (ISLH) meeting in Nice, France last May.
Post-launch evaluations
Hospital Clinic of Barcelona used the Siemens Advia 2120 as comparison instrument during the evaluation. The BC-6800 results were also compared to those of microscopic examination. The evaluation showed very good correlation both with the Advia 2120 and microscope results. The hospital also performed a reticulocyte study which showed a correlation coefficient of 0.966 between the BC-6800 and microscopic examination.
At the San Paolo hospital based in Naples, Italy, the BC-6800’s performance was compared with the Horiba Pentra 120, and with the Horiba Pentra DX 120, Abbott CELL DYN Sapphire and Beckman Coulter LH 750 at the Second University Hospital of Naples. The comparison established good correlation of the BC-6800 with all of them. Moreover, the BC-6800 is under evaluation in France and Australia, where more pathological samples are tested to check the instrument’s working efficiency on such samples.
Read more
ToRCH EIA TEST KITS
, /in Product News /by 3wmediaA high quality ToRCH panel that is manufactured in the USA and employs ELISA methodology is now available. The Elisa methodology provides excellent sensitivity, specificity, accuracy and precision. The assay kits offered will determine IgG and IgM antibodies to Toxoplasma, IgG and IgM antibodies to Rubella, IgG and IgM antibodies to CMV and IgG antibody to HSV. ToRCH is an acronym for a group of infectious diseases that can cause illness in pregnant women and may cause birth defects in their newborns.
Read more
Routine coagulation analysis
, /in Product News /by 3wmediaThe family of Coagulyzer instruments provides flexible solutions for the hemostasis laboratory. From the spacesaving Coagulyzer 1, a single channel instrument suited for a GP’s office to the Coagulyzer 100, a compact fully automated system ideal for a mid-volume laboratory, the line offers compact stand-alone systems which have been designed with a clear focus on being user friendly, reliable and cost effective. The four analysers combine the advantages of mechanical and photo-optical clot detection in the turbodensitometric measuring principle. For the routine assays PT, APTT and Fibrinogen, Analyticon offers a complete system with reagents, controls and calibrators. The recombinant PT is a state-of-the-art, liquid-stable reagent offering easy and safe handling of the reagent. In addition, it is formulated to be insensitive to therapeutic levels of heparin. Meeting the demands for precise and reliable results the Coagulyzer line of analysers and reagents provides robustness, reliability and ease-of-use.
Read more
Chemistry analyser system
, /in Product News /by 3wmediaDesigned for hospitals and clinical laboratories with high sample volumes, the BS-2000 modular system combines innovation and high performance into a fully integrated solution, together with the complete line of original reagents, calibrators with metrological traceability and controls. It offers a versatile solution with high efficiency, automation and scalability, while laying the foundation for further modular integration with future Mindray products. The instrument features high throughput from 2200T/H to 4400T/H with ISE, high sample capacity with 440 total sample positions, and high reagent capacity with 140 reagent positions. The system’s minimum reaction volume of just 80uL reduces cost per test while its intuitive soft ware makes for easy and convenient operation. Clot detection, crash protection and bubble detection ensure more accurate measurement for all the specimens, enhancing laboratory efficiency.
Read more