Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
November 2025
The leading international magazine for Clinical laboratory Equipment for everyone in the Vitro diagnostics
Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.
Accept settingsHide notification onlyCookie settingsWe may ask you to place cookies on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience and to customise your relationship with our website.
Click on the different sections for more information. You can also change some of your preferences. Please note that blocking some types of cookies may affect your experience on our websites and the services we can provide.
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to provide the website, refusing them will affect the functioning of our site. You can always block or delete cookies by changing your browser settings and block all cookies on this website forcibly. But this will always ask you to accept/refuse cookies when you visit our site again.
We fully respect if you want to refuse cookies, but to avoid asking you each time again to kindly allow us to store a cookie for that purpose. You are always free to unsubscribe or other cookies to get a better experience. If you refuse cookies, we will delete all cookies set in our domain.
We provide you with a list of cookies stored on your computer in our domain, so that you can check what we have stored. For security reasons, we cannot display or modify cookies from other domains. You can check these in your browser's security settings.
.These cookies collect information that is used in aggregate form to help us understand how our website is used or how effective our marketing campaigns are, or to help us customise our website and application for you to improve your experience.
If you do not want us to track your visit to our site, you can disable this in your browser here:
.
We also use various external services such as Google Webfonts, Google Maps and external video providers. Since these providers may collect personal data such as your IP address, you can block them here. Please note that this may significantly reduce the functionality and appearance of our site. Changes will only be effective once you reload the page
Google Webfont Settings:
Google Maps Settings:
Google reCaptcha settings:
Vimeo and Youtube videos embedding:
.U kunt meer lezen over onze cookies en privacy-instellingen op onze Privacybeleid-pagina.
Privacy policy
Fecal calprotectin quantitation
, /in Product News /by 3wmediaMeasurement of fecal calprotectin allows reliable discrimination of patients with inflammatory bowel disease (IBD) and irritable bowel syndrome (IBS), an early detection of relapse in IBD-patients as well as an objective therapy monitoring. RIDASCREEN Calprotectin comes equipped with an economical calibrator for evaluation by 1-point calibration. Each kit additionally contains a set of 5 standards for quantitative determination of fecal calprotectin (FC) by means of a standard curve. The test is validated for manual as well as automated use. Optionally the RIDASCREEN stool collection tubes are available. They are prefilled with extraction buffer which allow for fast, clean and precise sample collection.
Read more
Cleanly removable laboratory labels
, /in Product News /by 3wmediaThe CILS-9100R label range, provide exceptional highstrength bonding to all plastic/ glassware, yet can be cleanly peeled off at any time, leaving no adhesive residue – saving valuable time and money. Variable data (barcodes, serial numbers etc) can be printed ‘in minutes’ straight from a standard laser or thermal transfer printer, eliminating the risk of smudged/illegible handwritten data during sterilization/decontaminating cycles, extreme temperatures (-45°C to +155°C), chemical exposure etc. Manufactured to any size, shape and colour-coded design, CILS-9100R labels provide laboratories with the ultimate temporary labelling solution.
Read more
Coagulation reagents
, /in Product News /by 3wmediaThe management and control of anticoagulant therapy and the assessment of pre and post surgical states, among others, require a proper evaluation of the coagulation cascade. Several tests help the physician in the diagnosis of altered coagulation states and management of coagulopathy. Biosystems’ recently launched coagulation reagents line includes the main diagnostic tests: Prothrombin Time, Activated Partial Thromboplastin Time, Fibrinogen and Thrombin Time. These reagents can be used in semiautomatic and automatic coagulation instruments, independently of the kind of clot detection method (optical and mechanic). Additionally, they are characterized by high stability and a good performance using low volume consumption.
Read more
Parameter menu extended to antiarrhythmics and anti-HIV drugs
, /in Product News /by 3wmediaThe parameter menu of the MassTox TDM Series A from Chromsystems has been extended to include antiarrhythmic and anti-HIV drugs. These new parameter sets allow the fast and effective LC-MS/MS analysis of 25 antiarrhythmics and 18 anti- HIV drugs. They complement the modular system of MassTox TDM Series A, which enables the determination of more than 150 parameters with a single column and one sample preparation method. The parameter sets are provided with matrix-adapted 3PLUS1 / 6PLUS1 Multilevel Calibrator Sets and MassCheck controls. Customers can choose the MassTox TDM parameter sets from the parameter menu as needed, such as anti-HIV drugs, antiarrhythmic drugs, antimycotic drugs, neuroleptics, and more.
Read more
Blood gas analyser
, /in Product News /by 3wmediaStat Profile Prime is a new blood gas analyser that combines the microelectronics of the consumer world with Nova’s innovative ZERØ maintenance cartridge technology for a smaller, faster, and less expensive critical care analyser. Stat Profile Prime’s ZERØ maintenance cartridge technology consists of individual cartridges for biosensors, calibrators, and liquid quality control. Each cartridge is maintenance- free, ready to use, and easily replaced in seconds. This design optimizes the life of each cartridge; improves analyser uptime; and eliminates the waste, downtime, and higher costs of older combined calibrator/sensor cartridge systems. Nova’s new technology MicroSensor Card contains biosensors for pH, PCO2, PO2, Na, K, iCa, Cl, Glu, and Lac. Credit card-sized, the MicroSensor Card is automatically calibrated and always ready to deliver a full 10-test profile in just 60 seconds. MicroSensor cards can be replaced in less than half the time of older cartridge systems, which can take more than one hour to calibrate and can remain unstable with drift , frequent re-calibrations, and reduced throughput for even longer periods of time. Stat Profile Prime’s Clot Block sample flow path protects the Micro- Sensor Card from blockages and prolonged downtime caused by blood clots. Compact, lightweight, and simple to operate with a colour touchscreen, Stat Profile Prime may be used in a fixed location virtually anywhere in the hospital or operated on a mobile cart with a battery back-up. The analyser ensures the highest quality and lab accuracy with automated, true liquid quality control and continuous electronic self-monitoring, saving time and labour. Tests include: partial pressure of carbon dioxide and oxygen, acidity, sodium, potassium, chloride, ionized calcium, glucose, lactate, and hematocrit.
Read more
HSV 1 & 2 direct molecular test for aiding the diagnosis of encephalitis
, /in Product News /by 3wmediaThe Simplexa HSV 1 & 2 direct molecular test running on the 3M Integrated Cycler is the first molecular test to be cleared by the FDA for the qualitative detection and differentiation of herpes simplex virus 1 (HSV-1) and herpes simplex virus 2 (HSV-2) in cerebrospinal fluid (CSF) from patients suspected of HSV central nervous system (CNS) infection, including encephalitis. The test uses a proprietary process that eliminates nucleic acid extraction, so clinicians can expect results within about an hour after providing a specimen for testing. Encephalitis is an inflammation of the brain oft en caused by the herpes simplex or other viruses. The Infectious Diseases Society of America (IDSA) recommends herpes simplex PCR testing on all CSF specimens in patients with encephalitis. HSV encephalitis occurs in all ages and during all seasons, with HSV-1 encephalitis more common in adults and HSV-2 encephalitis more common in newborn infants. Accurate determination of the virus-causing encephalitis can influence treatment decisions and outcomes. The moderate complexity categorization of the Simplexa HSV 1 & 2 Direct molecular test significantly broadens the potential clinical access to the technology. Moderate complexity laboratories, defined by the Clinical Laboratory Improvement Amendments (CLIA), include certain types of physician’s offices, community hospitals, health clinics and integrated delivery networks. These facilities typically lack the personnel and technology to perform high complexity molecular diagnostic tests. Since the test can be performed in these moderate complexity labs, patient results may be obtained readily to help speed therapeutic decisions. Simplexa tests, designed for use on the 3M Integrated Cycler, employ realtime polymerase chain reaction (PCR) technology to detect DNA or RNA in viruses, bacteria, and other analytes. Simplexa HSV 1 & 2 Direct showed strong performance in clinical studies, with 100% and 98% sensitivity for detection of HSV-1 and HSV-2 respectively. The test was CE-marked for distribution to more than 30 countries in Europe in November 2013.
Read more
Blood cell image analysis system
, /in Product News /by 3wmediaVision Hema Pro is an optimal solution for small- and medium-sized laboratories. All stages of blood smear analysis are optimized: automatic scanning series of slides without the constant presence of the operator, identification and pre-classification of blood cells, validation of analysis results, data archive and report generation. Analysis is accurate and objective thanks to automatic recognition and pre-classification of blood cells. Microscopic blood smear analysis documentation and specialized soft ware provide greater assurance in analysis results. Featuring correctly organized workplace ergonomics, the Vision Hema Pro system reduces the load on neck and hand muscles that accompanies routine microscopy. The working time of experienced and qualified professionals is used more effectively.
Read more
Automated urine sediment analyser
, /in Product News /by 3wmediaThe Urilyzer Sed automates the Gold Standard in measuring and describing formed elements in urine, i.e. microscopy. The instrument is a precise and accurate analyser which classifies particles from native urine with microscopy technology and an automated image recognition soft ware based on a morphological analysis of the cells. Real whole-field images are captured via a CCD camera in low- and high power scan and are available for on-screen verification on the PC monitor of the system. The system has a long-life counting chamber consisting of three measuring channels and uses only one major system liquid to clean those channels after each measurement. All Urilyzer Sed reagents are space- and weight efficient concentrated solutions. The Urilyzer Sed is an affordable solution for hospitals, laboratories and clinics. It streamlines the workflow, helps to standardize the procedure and increases the efficiency of the user in contrast to manual microscopy.
Read more
Compact hematology analyser
, /in Product News /by 3wmediaThe BC-5150 5-part hematology analyser is offered as a compact solution for clinical labs, especially those with limited spare space. Its compact footprint is a result of innovative technology improvements, including miniaturized semi-conductor laser source, highly integrated electronic boards and optimized liquid handling systems. The tri-angle laser scatter is the key technology used on BC-5150, enabling better 5-part WBC differentiation even on samples with high eosinophils. The instrument has very user-friendly software and hardware. With a 10.4-inch TFT full-colour touch screen, the need for an external PC is practically eliminated. The BC-5150 inherits its convenient and proven powerful software design from the BC-6800 & BC-3600 platforms, specifically modified for easier handling in small sized labs. Four USB ports located on the left side allow convenient data transmission as well as connections to printers, keyboard, mouse, barcode scanner, etc. The BC-5150 has 2 test modes for capillary blood sample, capillary whole blood mode and pre-diluted mode. In the capillary whole blood mode, the user can aspirate capillary blood sample directly through the sample probe. In order to provide an economical solution for labs, the liquid handling system minimizes reagent consumption during sample testing, start up and shut down procedures.
Read more
Vitamin D ELISA
, /in Product News /by 3wmediaRequiring no external sample preparation and no organic solvents, the Calbiotech 25-OH Vitamin D ELISA is a sensitive, robust, user friendly and automation-ready assay. Total assay time is 2.5-hours, with all incubations performed at room temperature. This test is based on the principle of competitive binding. Anti-Vitamin D antibody-coated wells are incubated with Vitamin D standards, controls, samples, and vitamin D-Biotin conjugate at room temperature for 90 minutes. Following a wash step, bound Vitamin D-Biotin is detected with Streptavidin-HRP. Streptavidin-HRP conjugate immunologically bound to the well progressively decreases as the concentration of Vitamin D in the specimen increases. Unbound SA-HRP conjugate is then removed and the wells are washed. Next, a solution of TMB Reagent is added and incubated at room temperature for 30 minutes, resulting in the development of blue colour. The colour development is stopped with the addition of stop solution, and the absorbance is measured spectrophotometrically at 450 nm. In an independent study, the Calbiotech 25(OH) Vitamin D ELISA showed excellent correlation to LC/MS/MS (R2=0.949; N=20), and performed better than a highly referenced, commercially available ELISA (R2=0.8314; N=20).
Read more