Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
March 2026
The leading international magazine for Clinical laboratory Equipment for everyone in the Vitro diagnostics
Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.
Accept settingsHide notification onlyCookie settingsWe may ask you to place cookies on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience and to customise your relationship with our website.
Click on the different sections for more information. You can also change some of your preferences. Please note that blocking some types of cookies may affect your experience on our websites and the services we can provide.
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to provide the website, refusing them will affect the functioning of our site. You can always block or delete cookies by changing your browser settings and block all cookies on this website forcibly. But this will always ask you to accept/refuse cookies when you visit our site again.
We fully respect if you want to refuse cookies, but to avoid asking you each time again to kindly allow us to store a cookie for that purpose. You are always free to unsubscribe or other cookies to get a better experience. If you refuse cookies, we will delete all cookies set in our domain.
We provide you with a list of cookies stored on your computer in our domain, so that you can check what we have stored. For security reasons, we cannot display or modify cookies from other domains. You can check these in your browser's security settings.
.These cookies collect information that is used in aggregate form to help us understand how our website is used or how effective our marketing campaigns are, or to help us customise our website and application for you to improve your experience.
If you do not want us to track your visit to our site, you can disable this in your browser here:
.
We also use various external services such as Google Webfonts, Google Maps and external video providers. Since these providers may collect personal data such as your IP address, you can block them here. Please note that this may significantly reduce the functionality and appearance of our site. Changes will only be effective once you reload the page
Google Webfont Settings:
Google Maps Settings:
Google reCaptcha settings:
Vimeo and Youtube videos embedding:
.U kunt meer lezen over onze cookies en privacy-instellingen op onze Privacybeleid-pagina.
Privacy policy
Performance studies indicate suitability of VERIS* for routine lab applications
, /in Featured Articles /by 3wmediaBeckman Coulter’s VERIS Molecular Diagnostic (MDx) System* is a fully automated system for quantitative and qualitative analysis of molecular targets. It integrates sample introduction, nucleic acid extraction, reaction setup, real-time PCR amplification and detection, and results interpretation. Abstracts of studies presented as posters at the recent European Congress of Clinical Microbiology and Infectious Diseases (ECCMID) in Barcelona highlighted the suitability of the system and its assays for use in the routine laboratory. Three of these abstracts appear below.
VERIS Molecular Diagnostic System sample-to-sample crossover contamination study
Summary
Sample carry-over and cross-contamination present a high risk for the laboratory. VERIS was developed to have a false positive rate due to cross contamination of less than 1 in 500 tests with an overall design goal of zero. This study involved several stages: to assess the sample-to-sample contamination rate using a real-time PCR assay and then characterize potential sources of contamination. System modifications were then to be developed to resolve any carry-over and cross-contamination and the system then retested.
Method and Results
Contamination characterization was performed by swabbing areas of the instrument before and after running a series of high concentration level positive samples to determine potential sources of contamination. Twenty high positive Cytomegalovirus (CMV) spiked samples at a concentration of 1×1010 IU/mL were used in this testing. A total of 27 high risk areas on the instrument were evaluated. High risk areas were defined as areas on the system where liquid handling occurs and where potential splashing of sample or reagents can occur. The swabs were placed in the TE buffer and then processed on the VERIS system. Swab assessments identified several areas where splashing and contamination of high positive samples was occurring, with the potential to contaminate a future sample.**
This resulted in several modifications to the liquid handling parameters and motor speeds to eliminate the potential for sample-to-sample contamination. Swab testing was used to verify the effectiveness of the modifications. The study concluded that accurate results for true negative samples were now being shown, with no detectable carryover and contamination from high positive to negative samples. This was true when the concentration of CMV target in the samples was above clinical levels and the frequency of high positives in the sample population exceeded 30%.
Cytomegalovirus (CMV) viral load assay for the VERIS MDx System
Summary
The initial assay menu includes the VERIS Cytomegalovirus (CMV) Assay*, intended for use in conjunction with clinical presentation and other laboratory markers as an aid in monitoring CMV viral load and for the detection of virus reactivation. This study reported on performance in key analytical and clinical measures.
Method and Results
137 paired samples tested on both the VERIS CMV Assay and the Roche COBAS AmpliPrep/COBAS TaqMan CMV Test were used to demonstrate method comparison in accordance with CLSI EP9-A2. 287 specimens were tested to demonstrate the clinical specificity of the assay.
Assay measuring interval: the assay is linear for human CMV with a lower limit of quantitation (LLQ) of 120 IU/mL and an upper limit of quantitation (ULQ) of 10,000,000 IU/mL. A nine member panel of the CMV AD169 reference strain demonstrated a linear range of 159 to 13,400,000 IU/mL (2.20-7.13 Log IU/mL). A four-member panel of the 1st WHO International Standard for Human Cytomegalovirus (HCMV) (NIBSC 09/162) demonstrated a linear range from 120 and 10,000 IU/mL (2.08-4.00 Log IU/mL)
Precision: demonstrated a total (within-run and between-run) standard deviation of less than 0.15 Log IU/mL across its linear range.
Sensitivity: The VERIS CMV Assay was shown to have a Limit of Detection (LoD) of 30 IU/mL (1.48 Log IU/mL) across all subtypes tested.
Performance evaluation of the Beckman Coulter VERIS Cytomegalovirus Assay on the VERIS MDx System
Summary
Another study assessed the VERIS CMV assay for reproducibility and specificity, comparing it with the Roche COBAS AmpliPrep/COBAS TaqMan CMV test. In immune-compromised individuals, the activation of the latent virus, is a significant cause of morbidity and mortality. Real-time polymerase chain reaction (PCR) assays offer the ability to diagnose active infection and monitor those individuals at risk.
Method and Results
Using paired plasma samples, total assay imprecision was
≤ 4.6% CV with the SD ≤0.14. Clinical specificity with negative samples was 100% with a lower bound of the 95% CI = 98.7%. It had comparable recoveries to the Roche assay with a Passing-Bablock regression equation of VERIS=0.30+1.00 (Roche), r=0.88 and n=130.
*Not for sale or distribution in the U.S.; not available in all markets.
**References available on request
Fostering Georgia’s thriving hematology sector
, /in Featured Articles /by 3wmediaThe state of Georgia is committed to supporting and growing the booming life science industry. By continually investing in its people, resources and solutions that meet companies’ unique business needs, Georgia is becoming a leader in the hematology and immunology sector.
When it comes to the study of blood and curing blood-related diseases, access to the right research, qualified talent and effective cold chain logistics is imperative to solving tomorrow’s health challenges.
These are a few of the many reasons Baxter International’s $1.3 billion (€0.96 billion) plasma fractionation plant, the America Red Cross’ Biomedical Services, the second largest blood processing facility in the world by volume, and Qualtex Laboratories, the United States’ largest independent testing lab for blood and plasma products, have chosen Georgia to call home.
Georgia is well equipped to support hematology companies and advanced research initiatives in treating and curing serious illnesses. In fact, Georgia’s robust hematology sector accounts for 21 percent of the state’s life science workforce.
Talent and training
One of the vital resources that companies in the hematology sector are finding in Georgia is access to the most innovative research and development, as well as the best and brightest talent. Georgia life science companies continue to take advantage of our world-class institutions and universities and the number one workforce training program in the nation, QuickStart.
In fact, EMSI ranks Georgia medical and health-related degrees as the No. 1 area of study in the region, and Georgia Tech’s biomedical/bioengineering programs are in the top five in the nation.
Emory University (Emory) has long been recognized for its expertise in cellular immunity and immune memory at the Emory Vaccine Center (EVC). EVC is one the largest and most comprehensive academic vaccine centres in the world. Nine in 10 HIV patients undergo lifesaving therapy that includes drugs that were created at Emory University.
Public-private partnerships
By connecting state resources such as the Centers for Disease Control and Prevention with companies and universities engaged in life science exploration, Georgia has created a dynamic and collaborative environment to support this booming industry.
The Atlanta Clinical & Translation Science Institute (ACTSI), a collaboration between Emory, the Georgia Institute of Technology (Tech) and the Morehouse School of Medicine, is solely focused on transforming scientific discovery into a positive impact on the community.
The Lam Lab, located at Emory and Tech, offers the ideal environment to foster integration between microtechnology development and experimental hematology and oncology practices.
The Georgia BioScience Training Center, a 50,000-square-foot facility dedicated to supporting research and technology transfer in the bioscience industry, will provide comprehensive, customized workforce training critical to the successful operations of bioscience and biomanufacturing industries. The Center will help train employees for Baxter’s $1 billion biomaufacturing plant in Covington, Ga.
Cold chain logistics
Supplying life-saving vaccines and treatments to the world would not be possible without Georgia’s extensive cold chain network. Being home to 75 facilities that have temperature-controlled and frozen storage capabilities, Georgia has built a strong value chain and an interconnected infrastructure to better meet the demands of the hematology sector. The Hartsfield-Jackson Atlanta International Airport houses a 32,000-square-foot Atlanta Perishables Center. The center is the only facility in the Southeast approved by the USDA to apply cold treatment, an alternative to methyl bromide.
Georgia Department of Economic Development www.georgia.org/hematology
Automated Chemiluminenscence Immunoassay
, /in Featured Articles /by 3wmediaTandem mass spectrometer LCMS-8040
, /in Featured Articles /by 3wmediaVision Hema Pro: Blood cell image analysis system
, /in Featured Articles /by 3wmediaComparative study of a urine analyzer FUS-2000 (DIRUI) and an iQ 200 (Iris)
, /in Featured Articles /by 3wmediaWhat is the impact of assay failure in your laboratory?
, /in Featured Articles /by 3wmediaCDx solution for NSCLC, Melanoma and CRC testing
, /in Featured Articles /by 3wmediaVision Karyo – Chromosome analysis
, /in Featured Articles /by 3wmediaIntroducing the future of special protein analysis
, /in Featured Articles /by 3wmedia