p18 10

Alternative sampling strategies for antiepileptic drug monitoring

The continued use of first-generation antiepileptic drugs (AEDs) and their usually pronounced intra- and inter-individual variability, have made AEDs among the most common medications for which therapeutic drug monitoring (TDM) is performed. As the most cost-effective, rational and clinically useful methodologies are being pursued for TDM interventions, suitable sampling alternatives (e.g. dried blood samples and saliva) for the conventional venous sampling have been proposed.

by Sofie Velghe and Prof. Christophe P. Stove

Background
Administration of appropriate antiepileptic drugs (AEDs) is the mainstay in the attempt to provide epilepsy patients with a seizure-free, normal life. AEDs constitute a structurally and pharmacologically diverse group of drugs for which different criteria for classification are used, e.g. classification based on time of introduction by the pharmaceutical industry (i.e. first-, second- and third-generation of AEDs) [1]. In this way, carbamazepine (CBZ), phenytoin (PHT), phenobarbital (PB) and valproic acid (VPA) belong to the first-generation of AEDs, because of their introduction prior to 1990 [1]. Examples of the second-generation of AEDs are, among others, oxcarbazepine, vigabatrin and topiramate, whereas lacosamide, retigabine and eslicarbazepine are categorized as third-generation AEDs [1]. Another, clinically relevant classification is based on their spectrum of activity. Here, a distinction can be made between AEDs with a broad (i.e. effective against multiple types of seizures) and a narrow (i.e. effective against specific types of seizures for example focal epilepsy) spectrum [2]. Table 1 provides an overview of the licensed AEDs in Belgium, together with their plasma reference ranges, classified based on their activity spectrum. The treatment strategy of epilepsy is typically twofold: initially a treatment of acute tonic-clonic seizures, generally with benzodiazepines, is necessary, followed by an initiation of a chronic, preventive treatment with AEDs. Preferably, the latter consists of a monotherapy with one AED for which the dose is slowly titrated upwards when necessary. However, for some forms of epilepsy or in cases where a monotherapy at the maximum dosage is insufficient, a combination therapy with multiple AEDs is needed.

The generally narrow therapeutic indices, causing toxicity to be a common issue, together with their frequent use (i.e. for epilepsy, but also for pain and bipolar disorder) has made first-generation AEDs one of the most common medication groups for which therapeutic drug monitoring (TDM) is performed [3].

Owing to the large inter-individual variety in types of epilepsy and in the severity of epileptic seizures, the same dosage of an AED causes a symptom decrease in some patients, whereas in others epileptic seizures remain poorly controlled. Furthermore, some patients experience complete seizure control with an AED blood concentration below or above a set reference range, making TDM of AEDs quite challenging. Therefore, dosage adjustment should preferably be performed by combining the results of TDM with the clinical outcome. In other words, at the start of an AED treatment, a clinician must aim at obtaining an AED blood concentration within a set reference range, followed by a titration upwards or downwards, depending on the clinical symptoms. In this context, the concept of the ‘individual therapeutic concentration/range’ arose, being the AED concentration or range of concentrations for which an individual patient experiences an optimum response [4]. In order to define this ‘individual therapeutic concentration/range’, achieving the optimum desired clinical outcome can also be seen as an indication for TDM of AEDs. Determining the latter concentration or range can be performed for every AED, also including the AEDs for which a reference range is currently still lacking. To do so, the steady-state AED(s) concentration(s) should preferably be measured twice (2–4 months apart) once a patient has reached his/her optimum AED regimen [3].
Alternative sampling strategies for TDM of AEDs
Limitations coupled to the traditional way of performing TDM of AEDs (i.e. in plasma or serum samples) are the invasiveness of the sampling technique and the typically large amounts of blood that are sampled. In addition, sampling requires a phlebotomist, which obliges a visit to a hospital or doctor. Therefore, a growing interest in the use of non-invasive or minimally invasive alternative sampling strategies for TDM of AEDs has arisen. In this regard, dried blood spots (DBSs) are undoubtedly, besides oral fluid, the most widely used alternative matrix. On the one hand, benefits coupled to the use of DBSs are: (i) possibility of home sampling, since the samples are generally obtained by the use of a finger prick; (ii) non-contagious character, making it possible to send the samples via regular mail to a laboratory; (iii) only a small sample volume is necessary, which makes it very attractive for certain patients, such as those with anemia and young children; (iv) suitability for automation of sample processing and analysis; and (v) increased stability for many analytes, which can be of utmost importance for AEDs, given the controversy concerning the stability of some first-generation AEDs in serum collected via gel separator tubes [3, 5, 6]. On the other hand, DBS use also suffers from some challenges: (i) the small sample volume requires sensitive analytical instrumentation; (ii) risk of contamination; (iii) the hematocrit (Hct) effect; (iv) possibility of analyte concentration differences between capillary and venous blood; (v) adequate sampling is necessary, imposing the need for proper training of patients on the sampling technique; and (vi) influence of spotted blood volume and the punch location, especially when partial DBS punches are analysed [5, 6]. Among these challenges, the Hct effect is undoubtedly the most discussed issue related to DBS analysis. Variations in Hct influence the spreading of blood on the filter paper: blood with a higher Hct will spread less compared to blood with a lower Hct, impacting the spot size and spot homogeneity. Furthermore, the Hct may also influence matrix effect and recovery. With this impact in mind, many strategies to cope with this issue have been made over the past few years (reviewed in De Kesel et al. [7] and Velghe et al. [8]). Among these are volumetrically generated dried blood samples, which are analysed entirely. These could be DBSs on conventional filter paper [9], or, alternatively, samples generated via volumetric absorptive microsampling (VAMS) (Fig. 1), a technique by which a fixed volume of blood is wicked up via an absorbent tip [10]. We recently demonstrated the potential of VAMS for AED monitoring [11]. However, It needs to be stated that, if no large differences are anticipated in the Hct of the target population, it can be assumed that the impact of the Hct will remain limited and partial-punch analysis will likely not pose an issue for DBS-based AED analysis [12–14].
As TDM is most often performed on plasma or serum samples, reference ranges for AEDs are typically set for these matrices. Hence, if one wants to derive a plasma concentration from a (dried) blood concentration, there is a need for a ‘conversion’. This can be done by establishing average blood : plasma ratios or, alternatively, by plotting (dried) blood concentrations versus plasma concentrations of a reference set of samples and using the resulting calibration equation to derive ‘calculated plasma concentrations’ from a test set of samples. Obviously, this will also be accompanied with an additional level of uncertainty [11–14].

Alternatively, dried serum/plasma spots might be generated directly, using devices that contain filters that essentially allow passage of the liquid portion of blood but will stop the cellular portion [15–17]. Although several devices have been developed, it remains to be fully established (for AEDs, as well as for other analytes) whether the concentrations that can be derived from the resulting dried plasma/serum spots effectively mirror those in liquid plasma/serum.

Lastly, it should also be remarked that dried blood samples may also be used – without a need for conversion – for the follow-up of someone’s ‘individual therapeutic concentration/range’, once this has been established. On the one hand, this overcomes the need of using specialized dedicated devices, which typically come at an increased cost; on the other hand, this avoids the introduction of an additional level of conversion-associated uncertainty.

Conclusion
TDM of AEDs via DBS, VAMS or dried plasma/serum spots is an interesting application with the potential for a better follow-up of patients. Large-scale studies are warranted to substantiate the benefit for the patient and the corresponding potential associated cost savings.

References
1. Milosheska D, Grabnar I, Vovk T. Dried blood spots for monitoring and individualization of antiepileptic drug treatment. Eur J Pharm Sci 2015; 75: 25–39.
2. Commented drug code. BCFI 2018 (www.bcfi.be) [In Dutch/French].
3. Patsalos PN, Spencer EP, Berry DJ. Therapeutic drug monitoring of antiepileptic drugs in epilepsy: a 2018 update. TDM 2018; 40: 526–548.
4. Patsalos PN, Berry DJ, Bourgeois BF, Cloyd JC, Glauser TA, Johannessen SI, Leppik IE, Tomson T, Perucca E. Antiepileptic drugs – best practice guidelines for therapeutic drug monitoring: a position paper by the subcommission on therapeutic drug monitoring, ILAE Commission on Therapeutic Strategies. Epilepsia 2008; 49: 1239–1276.
5. Wilhelm AJ, den Burger JC, Swart EL. Therapeutic drug monitoring by dried blood spot: progress to date and future directions. Clin Pharmacokinet 2014; 53: 961–973.
6. Velghe S, Capiau S, Stove CP. Opening the toolbox of alternative sampling strategies in clinical routine: A key-role for (LC-)MS/MS. Trac-Trend Anal Chem 2016; 84: 61–73.
7. De Kesel PM, Sadones N, Capiau S, Lambert WE, Stove CP. Hemato-critical issues in quantitative analysis of dried blood spots: challenges and solutions. Bioanalysis 2013; 5: 2023–2041.
8. Velghe S, Delahaye L, Stove CP. Is the hematocrit still an issue in quantitative dried blood spot analysis? J Pharm Biomed Anal 2018; 163: 188–196.
9. Velghe S, Stove CP. Evaluation of the Capitainer-B Microfluidic device as a new hematocrit-independent alternative for dried blood spot collection. Anal Chem 2018; 90: 12893–12899.
10. Denniff P, Spooner N. Volumetric absorptive microsampling: a dried sample collection technique for quantitative bioanalysis. Anal Chem 2014; 86: 8489–8495.
11. Velghe S, Stove CP. Volumetric absorptive microsampling as an alternative tool for therapeutic drug monitoring of first-generation anti-epileptic drugs. Anal Bioanal Chem 2018; 410: 2331–2341.
12. Linder C, Andersson M, Wide K, Beck O, Pohanka A. A LC-MS/MS method for therapeutic drug monitoring of carbamazepine, lamotrigine and valproic acid in DBS. Bioanalysis 2015; 7: 2031–2039.
13. Linder C, Wide K, Walander M, Beck O, Gustafsson LL, Pohanka A. Comparison between dried blood spot and plasma sampling for therapeutic drug monitoring of antiepileptic drugs in children with epilepsy: A step towards home sampling. Clin Biochem 2017; 50: 418–424.
14. Linder C, Hansson A, Sadek S, Gustafsson LL, Pohanka A. Carbamazepine, lamotrigine, levetiracetam and valproic acid in dried blood spots with liquid chromatography tandem mass spectrometry; method development and validation. J Chrom B 2018; 1072: 116–122.
15. Ryona I, Henion J. A Book-type dried plasma spot card for automated flow-through elution coupled with online SPE-LC-MS/MS bioanalysis of opioids and stimulants in blood. Anal Chem 2016; 88: 11229–11237.
16. Kim JH, Woenker T, Adamec J, Regnier F. Simple, miniaturized blood plasma extraction method. Anal Chem 2013; 85: 11501–11508.
17. Hauser J, Lenk G, Hansson J, Beck O, Stemme G, Roxhed N. High-yield passive plasma filtration from human finger prick blood. Anal Chem 2018; 90: 13393–13399.

The authors
Sofie Velghe PharmD and Christophe P. Stove* PharmD, PhD
Laboratory of Toxicology, Department of Bioanalysis, Faculty of Pharmaceutical Sciences, Ghent University, 9000 Ghent, Belgium

*Corresponding author
E-mail: christophe.stove@ugent.be

C365 Cawood Fig1

Benefits of specific drugs of abuse analysis by tandem mass spectrometry in urine and oral fluid

Quantitative specific drug analysis by tandem mass spectrometry allows a wide range of drugs to be analysed in either urine or oral fluid to confirmation standards. The repertoire of drugs is based on drugs of abuse implicated in drug-related deaths in Scotland and currently includes 27 specific drugs and metabolites.

by Dr Paul Cawood and Joanne McCauley

Background
Drugs of abuse have traditionally been identified by immunoassay screening methods. Some of these are relatively non-specific and require second-line confirmatory tests, traditionally by gas chromatography–mass spectrometry (GC-MS). As drugs are not volatile this requires derivatization to render the drugs volatile. Tandem mass spectrometry (TMS) has the advantage that samples can be analysed directly without derivatization.

Drug-related deaths in Scotland are the highest in Europe and are increasing steeply [1, 2], even though the number of substance misusers has not changed recently. Most deaths are due to accidental overdosing with opiates, which causes death from heart or respiratory failure. The steep increase is the result of poly-drug use, with gabapentin/pregabalin and street benzodiazepines (such as etizolam and alprazolam) implicated in a large number of these deaths. Identification of many of these drugs is not possible by traditional immunoassay screening methods even with GC-MS confirmation. However, it is possible to identify many of these drugs by TMS.

Specific quantitative drug analysis by TMS
Urine and oral fluid drugs of abuse method
A rapid method for the analysis of drugs of abuse in urine has been reported previously [3]. This method has been modified for the analysis of drugs implicated in drug-related deaths in Scotland [2]. One transition per drug can increase the risk of false-positive results [4]; hence,   each drug has two transitions and a closely matched deuterated internal standard in order to avoid these issues. Calibrators and quality control samples are made from Ceriliant certified standards. The standard set comprises morphine, codeine, 6-monoacetyl morphine (6-MAM), dihydrocodeine (DHC), oxycodone, gabapentin, pregabalin, methadone, EDDP (2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine, methadone metabolite), buprenorphine, norbuprenorphine, tramadol, amphetamine, 3,4-methylenedioxymethamphetamine (MDMA, or ecstasy) , methamphetamine, cocaine, benzoyl ecgonine (BEC), diazepam, nordiazepam, temazepam, oxazepam, 7-amino-clonazepam, nitrazepam, alprazolam, diclazepam, delorazepam and etizolam. Stock standard solution is made by adding 100 µg of each standard to a 20 ml volumetric flask, resulting in 5 000 µg/L. Calibrators are prepared at: 5, 10, 20, 30, 100, 300 and 1000 µg/L with quality controls at 10, 20, 50, 100, 300 and 400 µg/L in 3 % human serum albumin. The albumin prevents non-specific binding to the container.

Spot urine samples are collected in universal containers and oral fluid is collected into a Sarstedt salivette cortisol collection device (without preservative).

50 µL of calibrator, quality control, patient urine or oral fluid has 20 µL of zinc sulphate (0.1 mol/L) and 150 µL internal standard mixture (containing 17 deuterated internal standards – 1 µg/100 mL methanol) added. The sample is mixed and centrifuged. 75 µL of supernatant is removed and added to 300 µL of water. A volume of 20 µL is injected.

TMS analysis
Samples are analysed on a Waters Xevo tandem mass spectrometer using a Waters Acquity ultra high performance liquid chromatography HSS C18 1.8 µm, 100 mm column at 50 °C. The sample is eluted using a multi-step gradient of water (1 % formic acid 2 mM ammonium acetate) and acetonitrile (1 % formic acid), starting at 98 % water/2 % acetonitrile to 63 % / 37 % at 3.4 min then to 5 % / 95 % at 4.5 min, reverting to 98 %/2 % at 5.2 min (Fig. 1).

Drugs are identified using the quantitative ion transition having the same peak shape as the qualitative ion transition; retention times need to match the corresponding deuterated internal standard and the quantifying ion to qualifying ion ratio matches that of the calibrators (Fig. 2). Drugs are reported as positive when above the corresponding threshold level. Threshold levels are broadly based on Driving Under the Influence of Drugs (DRUID) or European Workplace Drug Testing Society (EWDTS) confirmation test levels for both urine and oral fluid (Table 1).

We analyse 4 000 urine and 17 000 oral fluid samples each year. These are predominantly from drug problem users (Fig. 3).

Drugs of abuse in urine

TMS has the advantage of greatly reducing false-positive results seen with immunoassay methods and negating the need for second-line confirmatory tests. However, the use of urine as a sample medium still has a number of disadvantages: it is susceptible to adulteration or spiking with drugs; sample collection is not witnessed; urine drug concentrations vary depending on hydration status. This can affect whether a drug is reported as positive or negative relative to threshold levels. Additionally, some drugs are excreted relatively unchanged in urine, whereas other drugs are highly metabolized and conjugated, in which case unchanged parent drug levels can be low. In order to keep the sample preparation simple it was decided not to hydrolyse drugs in urine but to measure predominantly parent drugs, including metabolites only where necessary. This required threshold levels to be adjusted to give comparable positivity to immunoassay methods (Table 1).

Drugs of abuse in oral fluid
Oral fluid overcomes many of the disadvantages of urine: sample collection can be witnessed; samples cannot be adulterated or spiked; and threshold levels are not affected by hydration status. Since we have offered an oral fluid service most clinicians have switched from urine to oral fluid testing. Parent drugs predominate in oral fluid, with metabolite levels being generally absent or uninformative, with the exception of BEC and nordiazepam. Drugs are predominantly weak bases and diffuse from serum (pH 7.4) into oral fluid (pH 4.0–6.0). As such, some drugs are then unable to diffuse back out again. This can result in oral fluid drug levels being higher in oral fluid than in blood. Levels can remain positive for longer in oral fluid than in blood or urine, giving a longer duration of detectability for some drugs (Table 1) [5].

Opiates
Heroin contains diacetyl morphine and acetyl codeine. Both of these are rapidly metabolized into 6-MAM and codeine respectively. Both 6-MAM and codeine further metabolize to morphine. Morphine is the major excretory product of heroin in urine and is detectable in urine up to 72 h after heroin has been taken [6]. Finding 6-MAM confirms heroin has been taken. Finding codeine in the absence of 6-MAM is also compatible with codeine consumption. 6-MAM is the major heroin component in oral fluid and this always indicates heroin use. Morphine and codeine levels are generally lower than 6-MAM in oral fluid. Finding morphine in oral fluid, in the absence of 6-MAM or codeine usually indicates a pure morphine preparation has been taken. Long detection times for 6-MAM in oral fluid have been reported in a Norwegian study which analysed daily blood, urine and oral fluid samples in 20 heroin overdose cases. They reported that 6-MAM can remain positive in oral fluid for 5 days or more after heroin had been taken. In one case, the heroin test was positive 8 days after exposure [7]. Dihydrocodeine, tramadol and oxycodone can be readily identified in both urine and oral fluid.

Cocaine
Cocaine is rapidly metabolized into BEC. BEC is better than cocaine as a urine marker of cocaine use, and can be detected for 48–72 h after cocaine use [6]. However, cocaine predominates in oral fluid at much higher levels than BEC. Cocaine can remain positive in oral fluid for up to 5 days after cocaine has been taken.

Methadone/buprenorphine
Methadone and buprenorphine are prescribed for the treatment of opioid dependence and are metabolized into EDDP and norbuprenorphine, respectively. EDDP/methadone and norbuprenorphine/buprenorphine concentrations are measured in urine. Usually EDDP levels are significantly higher than methadone. Norbuprenorphine levels are usually much higher than buprenorphine. Finding methadone/buprenorphine levels greater than EDDP/norbuprenorphine indicates the sample has been spiked. Parent methadone and buprenorphine appear in oral fluid whereas EDDP and norbuprenorphine do not. Buprenorphine is administered sublingually and levels in oral fluid are very high in samples collected immediately after administration. To avoid this, oral fluid samples should not be collected within 1 h of the buprenorphine dose. Buprenorphine half-life varies from 2 to 24 h [8] and oral fluid can be negative for buprenorphine if the sample is collected the next day after a low dose.

Amphetamines
Amphetamine, MDMA and methamphetamine are excreted relative unchanged in urine. Hence, parent drugs are analysed in both urine and oral fluid.

Gabapentinoids
Gabapentin and pregabalin are predominantly excreted unchanged in urine so the parent drug is readily detected in both urine and oral fluid. A survey of substance misusers in Lothian in 2012 indicated that gabapentin was taken to potentiate the high obtained from methadone and to increase the level of intoxication [9]. 92 % of sample positive for gabapentinoids are also positive for methadone or buprenorphine confirming that these drugs are taken to boost the intoxicating effects of opiate and opioids.

Benzodiazepines
These drugs are highly metabolized and conjugated with only a small amount of parent drug excreted unchanged in urine. As such threshold levels are much lower than immunoassay screening methods. Diazepam metabolizes into nordiazepam and temazepam, both of which metabolize into oxazepam. Nordiazepam is also a metabolite of chlordiazepoxide. Finding diazepam, nordiazepam, temazepam and/or oxazepam is consistent with diazepam. Finding nordiazepam in the absence of diazepam is also consistent with chlordiazepoxide. Nordiazepam has a longer half-life than both diazepam and chlordiazepoxide and remains positive for longer than either parent drug. Detecting temazepam only, nitrazepam only or oxazepam only is consistent with those drugs being taken. These patterns persist in both urine and oral fluid, although threshold levels are lower in oral fluid compared to urine (Table 1).

Street benzodiazepines
Following the 2016 drug-related deaths Scotland report [1] we introduced testing for etizolam, delorazepam, diclazepam and alprazolam into the standard set. These drugs are generally not available by prescription in the UK. Alprazolam and etizolam are short acting, whereas delorazepam and diclazepam are long acting. Alprazolam is six times more potent than diazepam [10].

Conclusion and future developments
Gabapentinoid use is widespread and is almost always used to potentiate methadone and other opiates or opioids. There is an increasing trend for more potent street benzodiazepines. This poly-drug use has a detrimental effect on judgement and behaviour leading to inadvertent overdosing. Poly-drug use is the main reason for the increase in drug-related deaths in Scotland in recent years [2]. Identifying the main drugs implicated in these deaths is only possible by TMS. In the future, additional drugs can be considered for inclusion, such as phenazepam (30 deaths in 2017); flubromazepam (9); fentanyl (15); mirtazapine (59); amitriptyline (36); sertraline (12); fluoxetine (12); olanzapine (9); quetiapine (11) and zopiclone (29). There is evidence that these are being abused by substance misuse clients and these are all implicated in significant numbers of drug-related deaths in Scotland [11].

References

1. Drug-related deaths in Scotland in 2016. A National Statistics report for Scotland. National Records of Scotland 2017 (https://www.nrscotland.gov.uk/files//statistics/drug-related-deaths/drd2016/drug-related-deaths-16-pub.pdf).
2. Drug-related deaths in Scotland in 2017. A National Statistics report for Scotland. National Records of Scotland 2018 (https://www.nrscotland.gov.uk/files//statistics/drug-related-deaths/17/drug-related-deaths-17-pub.pdf).
3. Eichhorst JC, Etter ML, Rousseaux N, Lehotay DC. Drugs of abuse by tandem mass spectrometry: a rapid, simple method to replace immunoassays. Clin Biochem 2009; 42: 1531–1542.
4. Sauvage FL, Gaulier JM, Lachatre G, Marquet P. Pitfalls and prevention strategies for liquid chromatography-tandem mass spectrometry in selected reaction-monitoring mode for drug analysis. Clin Chem 2008; 54(9): 1519–1527.
5. Bosker WM, Huestis MA. Oral fluid testing for drugs of abuse. Clin Chem 2009; 55(11): 1910–1931.
6. Baselt RC, Cravey RH. Disposition of toxic drugs and chemicals in man. 4th edition. Chemical Toxicology Institute 1995; IBSN: 978-0962652318.
7. Baird CRW, Fox P, Colvin LA. Gabapentinoid abuse in order to potentiate the effects of methadone: a survey among substance misusers. Eur Addict Res 2014; 20(3): 115–118.
8. Kuhlman JJ Jr, Lanlani S, Magluilo J, Levine B, Darwin WD. Human pharmacokinetics of intravenous, sublingual and buccal buprenorphine. J Anal Toxicol 1996; 20(6): 369–378.
9. Vindenes V, Enger A, Nordal K, Johansen U, Christophersen AS, Øiestad EL. Very long detection times after high and repeated intake of heroin and methadone, measured in oral fluid. Forensic Sci 2014; 20(2): 34–41.
10. Aden GC, Thein SG Jr. Alprazolam compared to diazepam and placebo in the treatment of anxiety. J Clin Psychiatry 1980; 41(7): 245–248.
11. Barnsdale L, Gounari X, Graham L. The National Drug-Related Deaths Database (Scotland) Report. Analysis of deaths occurring in 2015 and 2016. Information Services Division, NHS National Services Scotland 2018 (https://www.isdscotland.org/Health-Topics/Drugs-and-Alcohol-Misuse/Publications/2018-06-12/2018-06-12-NDRDD-Report.pdf).

The authors
Paul Cawood* PhD
Joanne McCauley BSc
Department of Clinical Biochemistry, Royal Infirmary of Edinburgh, Edinburgh, UK

*Corresponding author
E-mail: Paul.cawood@nhs.net

27596 Greiner 140x204 VACUETTE SAFELINK en

VACUETTE® SAFELINK holder with male luer lock

27788 Cellavision CLI white

Meet CellaVision® DC-1

Full Automation of IFA with EUROPattern

27634 Stago 18 12039 AP Max Generation EN 140x204 HD

The Max Generation is now complete

27627 DIAsource 178x92 Annonce DiaSource ChromogranninA CLImagazine

The most complete solution for the measurement of Chromogranin A

27791 Randox Reagents Full Page Advert CLI March 2019

Advance your lipid testing profile with Randox

27816 Stago AnnonceDDiDiet140x204EN HD

A reliable testing system for enhanced patient care