C058 DiaSorin HSV VZV

HSV molecular assay

Further extending the range of infectious disease diagnostic assays for use on the DiaSorin Liaison Iam analyser, the Iam HSV molecular assay provides rapid and reliable differential detection of herpes simplex virus types 1 and 2 (HSV-1 and HSV-2) in human cerebrospinal fluid (CSF), vesicle swabs, plasma and whole blood, making it of enormous value in the diagnosis of herpes simplex encephalitis and potentially severe HSV infections in transplant patients and other immunocompromised individuals.  Together with Iam VZV for the detection of clinically relevant subtypes of Varicella Zoster Virus (VZV), these assays provide valuable information for the timely treatment of severe alpha-herpesvirus infections. HSV-1 is an important cause of fatal sporadic encephalitis, although HSV-2 is more commonly associated with herpes simplex encephalitis in neonates and immunosuppressed individuals.  Early diagnosis and treatment are important to reduce and prevent neurological damage.  In transplant patients and other immunocompromised hosts, HSV may cause severe infections, frequently disseminating to the visceral organs, and can be life or organ threatening. Nucleic acid tests are the method of choice for the diagnosis and characterization of HSV infection, following baseline serology, offering greater sensitivity than viral culture.  Furthermore, molecular detection of HSV DNA in CSF is recommended for the diagnosis of herpes simplex encephalitis.  The ability to differentiate between HSV types can provide important prognostic information, particularly in the diagnosis of genital herpes. Like HSV, VZV is the cause of significant morbidity and mortality in transplant patients and other immunocompromised individuals.  Immunocompromised children, particularly those with leukemia, are reported to be at risk of visceral complications and even death folllowing VZV infection. Complications occur in about 20% of VZV infected immunocompromised patients and include interstitial or necrotizing pneumonia, viral hepatitis with acute liver failure, coagulopathies and bacterial superinfections. Offering excellent diagnostic sensitivity (>95% for Iam VZV and >98.5% for Iam HSV) and specificity (100% for Iam VZV and 100% for Iam HSV), and with faster time to results than conventional real-time PCR, the assays provide rapid and accurate molecular confirmation of alpha-herpesvirus infections.  Furthermore, the small footprint, ease of use and scalable design of the benchtop Liaison Iam molecular instrument makes it ideal for use in laboratory facilities of all sizes, including those that are located close to the patient.  

Read more

C063 Siemens L1

Central laboratory analyser

Designed to enhance workflow and streamline processes to help laboratories quickly, reliably and cost-effectively meet ever-increasing workload demands, the ADVIA Chemistry XPT System is a fast system for the high-volume laboratory with a throughput of up to 2400 tests per hour. It achieves predictable turnaround times through a combination of micro-volume technology and aliquot retention. Sample aliquots are readily available onboard for testing and retesting; there is no need to return the tube to the system. The system also includes VeriSmart Technology, a combination of hardware and software checks to help ensure high-quality test results, and can be connected to the company’s CentraLink Data Management System, which streamlines workflow across automation, IT and instruments, and Siemens Remote Service (SRS).

Read more

C067 Thermo Scientific

Mass spectrometer LC-MS

The Endura MD mass spectrometer LC-MS for in vitro diagnostic use delivers excellent sensitivity for a wide range of compounds and matrices and minimizes signal noise by removing more solvent vapour and blocking neutrals. The instrument provides five orders of dynamic range for accurate quantitation of even low-concentration or limited samples and features ultrafast selected-reaction monitoring (SRM) so more transitions can be monitored for greater confidence. It accommodates both HESI and APCI probes, which can be operated in either positive or negative ion modes to meet varied analytical demands.

Read more

C061 EKF

Centrifuge

The new PlasmaPrep-12 centrifuge is suitable for use in both the hospital and laboratory. It is designed for STAT serum/plasma separation and is perfect for coagulation studies. Enabling fast blood separation and easy to use, it is controlled by a microprocessor with four pre-programmed spin times. These include the Platelet Poor Plasma mode providing serum or plasma separations in three minutes and the Platelet Rich Plasma mode providing platelet rich plasma in just 30 seconds.

Read more

C059 Dirui CLI Sept

Chemistry system

CS-6400 Auto-Chemistry System, utilizing advanced technology, offers an extremely efficient workflow to achieve the laboratory’s turnaround time goals. The cost-effective modular combination design and optional ISE module provide customers with flexible and multiple choices. The throughput of each photometric module is 1600 tests/hour and that of each ISE unit is 480 tests/hours. The highest throughput can reach 7360 tests/hour with 4 photometric modules and two ISE module units.

Read more

New High-Tech Labels for Secure Adhesion to Tubes, vials and curved surfaces down to -80°C!

New CILS-8100X labels naturally conform/bond to curved surfaces without detaching….

● Technically developed CILS adhesive for all laboratory environments and labware surfaces.

●  Unique CILS computer printable surface coating for ‘in-lab’ Laser & Thermal Transfer data printing!

●   Perfect for: Tubes, vials, Cryo-vials, Petri-dishes, Glass beakers, Barcoding, IVF liquid straws, Clinical trials, Bottles, beakers, etc.

●   Labels resistant to: Extreme Temperatures (-80°C to +155°C), Freezer storage, Laboratory solvents, Cleaning Agents, Water baths, Humidity & Moisture, Repeated Handling, etc.
Read more

Axis Shield HbA1c image

New assay for the measurement of Glycated Haemoglobin

Axis-Shield is excited to announce the launch of our new assay for the measurement of Glycated Haemoglobin (HbA1c) in human whole blood.
Regular monitoring of HbA1c levels is a key component of diabetic blood glucose control and the Axis-Shield assay provides a convenient method for use in routine testing laboratories. The Latex Turbidimetric Immunoassay methodology gives a highly accurate and precise method combined with a number of convenient features for the user and the lab. Operator handling time is reduced as the assay uses only 2 liquid-stable reagents so there is no requirement for pre-analytical mixing of reagents. Reagents are supplied in instrument-specific packaging so they can be directly loaded onto many systems without the need to further decant. The use of only two reagents also means that only one instrument channel is required, freeing space on your instrument.

The Axis-Shield assay removes the need for a simultaneous Total Hb measurement by utilising a monoclonal antibody against HbA1c.
The reagents can be used on any clinical chemistry instrument and programming is simple – applications for many common instruments are available from Axis-Shield. A 2-level control pack and 5-level calibrator pack are also available.
The Axis-Shield assay is certified by the National Glycohemoglobin Standardisation Program (NGSP).
Read more

C071 Biosystems

Lactate reagent

Blood lactate concentration is directly related to the availability of oxygen: when the amount of oxygen is inadequate in cells and tissues (hypoxia), the anaerobic carbohydrate metabolism leads to lactic acidosis. So, lactic concentration is increased in any type of tissue hypoxia, such as severe congestive heart failure, shock of any etiology (septic, cardiogenic…), severe anemia or monoxide carbon intoxication. Lactic acidosis can also happen in favourable tissue oxygenation, as in leukemia and solid tumours where the cause may be excessive lactate production by the neoplastic tissue. Other causes include poorly controlled diabetes or severe hepatic insufficiency. Lactate levels may also increase during intense exercise, causing a transitory and benign lactic acidosis. A cerebrospinal fluid (CSF) lactate test may be ordered, along with a blood lactate test, to help distinguish between viral and bacterial meningitis. Increased levels also occur in any clinical condition associated with reduced oxygenation of brain and/or increased intracranial pressure. This new lactate reagent is based on the Lactate Oxidase/Peroxidase method, which is more convenient for random access–type equipment because of its long stability on board and lack of cross contamination when compared with the Lactate Dehydrogenase method.
Read more

C072 Jokoh

Automated electrolyte analyser

This fully automated electrolyte analyser is available in two versions: model EX-D with autosampler and EX-Ds without autosampler. It is equipped with an ion selective electrode for measuring sodium, potassium, and chloride in whole blood, serum and diluted urine. Twenty samples can be processed in one run and results are available within 36 seconds/test. An auto-retest function allows for the automatic retesting of samples with abnormal values. Emergency samples can be tested at any time during routine measurement. Electrodes are highly sensitive and C.V is less than 0.5%. A radiofrequency identification (RFID) reader attached to the analyser and IC (integrated circuit) tags attached to reagents provides reagent identification. The IC tag records the expiry date and the concentration of the reagent at the time of shipment.
Read more

C020 West medica

Automated slide stainer for blood smears

V-Chromer III is a slide stainer with a pre-programmed standardized May-Grunwald Giemsa staining protocol. Protection of personnel and environment is supported by the utilization of charcoal filter for evaporation control while odours are neutralized. Featuring minimal reagent consumption, the instrument prevents contamination of reagents thanks to a drip system and doesn’t require connection to a water supply and drainage system.
Read more