miacom

Rapid test to identify pathogen from blood cultures

Based on fluorescence in situ hybridisation and designed to differentiate Staphylococcus aureus from coagulase-negative Staphylococci in positive blood cultures, the hemoFISH S.aureus/CNS Screen supports clinicians in effectively managing blood stream infections. The test also fits perfectly in today’s laboratory routine. Total turnaround time is only 15 minutes so that results can be reported together with the Gram stain. In addition, up to 12 blood cultures can be processed and analysed simultaneously, allowing microbiologists to apply this test in a batch mode. Importantly, the simple and robust assay procedure, which includes intrinsic controls in every test, is very accurate.Besides the hemoFISH product line, multiplex tests for semi-quantitative identification of pneumoniarelated pathogens directly from respiratory secretions are offered.
Read more

siemens logo

Lactate assay

A lactate assay is now available for Siemens’ recently launched RAPIDPoint 500 system for cartridge-based critical care testing at the point of care. Lactate joins an already extensive assay menu that includes blood gas, electrolytes, metabolites and CO-oximetry. The user-friendly system delivers rapid and accurate test results in approximately 60 seconds. The lactate assay further enhances the system’s functionality for clinicians relying on critical-care testing in, for example, Accident & Emergency departments or Intensive Care Units.
Read more

woodley

System to facilitate diagnosis of diseases in remote areas

Performing a haematology and biochemistry screen in 15 minutes is never normally achieved without sending samples off to a lab, which is virtually impossible in locations such as rural Africa. A health screening package based on dry reagent technology, the revolutionary design of the Insight Diagnostic System will now allow a full haematology, biochemistry and infectious disease profile to be performed within a short time period using just capillary blood at the point of care. The 3-component system combines the SpotChem EZ clinical chemistry analyser, the QBC Autoread Plus haematology analyser and the QBC ParaLens Advance fluorescence microscopy system. The dry reagent technology eliminates many of the issues faced by clinicians relating to storage space, biohazardous waste and spillages. The system does not require any regular servicing or maintenance. The clinical chemistry analyser is easy to use and provides the capability to test a total of 22 biochemistry parameters. The haematology system uses specially designed capillary tubes and can measure nine clinically significant haematology parameters in just seven minutes. Once the haematology process is complete, the same capillary tube containing the patient sample can be immediately examined for infectious disease parasites, including malaria, filariasis and trypanosamiasis, using the fluorescence microscopy system.
Read more

pro lab

Rapid test for norovirus

The number of reported norovirus cases is on the increase, with explosive outbreaks of this highly contagious pathogen leading to acute gastroenteritis. To improve outbreak management and help reduce transmission of the virus, a rapid assay for the detection of norovirus in faecal samples is now available. NOROTOP+ is a qualitative lateral flow assay allowing effective detection in just 15 minutes. This simple visual assay uses specific monoclonal antibodies to allow rapid, one-step detection of norovirus genogroups I and II, offering excellent sensitivity and specificity to facilitate quick and convenient identification and management of outbreaks. The individually packaged test strips can be safely stored at room temperature for up to 12 months, providing a practical and economical solution for norovirus testing whenever the need arises.
Read more

lgc

Range of certified reference materials

Manufactured and certified to ISO Guide 34, using ISO 17025 accredited processes in LGC’s own laboratories, the the LoGiCal range of certified reference materials offers scientists a choice of natural and deuterium labelled compounds, each supplied with a detailed Certificate of Analysis. The certified reference materials fully satisfy national and international labelling and other requirements for transportation, health and safety. The range focuses on the forensic and clinical sectors. Initially providing laboratories with access to over 800 of the most widely used standard reference materials, the new product range will comprise drugs of abuse and prescription drugs in standard solutions and powder format, with stocks maintained locally at LGC Standards international offices to help eliminate delays due to the complex, lengthy import procedures associated with the procurement of controlled substances.
Read more

Open system for ELISA processing

The Agility™ automated microplate processing system is an open system that utilizes state-of-the-art robotics, processing up to 12 microplates in a single run, delivering unparalleled precision while eliminating nearly all manual steps. The system is compatible with the new SmartKit™ technology, a packaging enhancement that provides a simple, direct-load solution to assay setup and operation. Up to 15 SmartKit assays can be loaded onboard, greatly improving throughput without sacrificing extra bench space. These pioneering advances reduce technician time and the potential for costly data entry errors, while improving ease-of-use and enhancing the product offerings of ELISA reagent kit manufacturers. 

For more information on the Agility system, see www.dynex-agility.com, or visit booth 3D45-7 at MEDICA 2012.
Read more

C302a GreinerBioOne

Secondary Tubes

Versatility is the great advantage of the new VACUETTE® Secondary Tubes developed by Greiner Bio-One. Th e tubes are available in two different types of material: PP (Polypropylene) and PET (Polyethylene terephthalate). They are perfectly suited for various uses inside and outside the laboratory, e.g. aliquoting, pooling, centrifuging, freezing, storing or transporting sample material. Thanks to the special screw closure, they fulfill the IATA guidelines for safe sample transport. Naturally they also meet the CLSI Standard AUTO 1-A. The tubes are easy to open, cold-resistant (-80 °C), transparent and shatter-proof. In order to off er the appropriate packaging for each application, Greiner Bio-One has developed two versions. VACUETTE® Secondary Tubes MULTIPLEX are packaged in pull-open plastic bags, whereas VACUETTE® Secondary Tubes SIMPLEX were developed especially for use with automated laboratory equipment. They are offered in environmentally friendly cardboard packaging. As they are already packaged pre-aligned in the cardboard container, they can be transferred directly into the storage container (plastic or metal box) of the laboratory machine. This is especially practical and saves valuable working time.
Read more

bio data 01

The PAP-8E – The Gold Standard for Platelet Aggregation

The PAP-8E from Bio/Data Corporation is the world’s most advanced 8 channel aggregometer for clinical, research and pharma laboratories as well as clinical trials. Exceptional ease of use and standardized test procedures allow for rapid and routine testing of platelet function. New features include On Demand Optical Calibration Check, Unlimited User Defined Test Types, Washed Platelet Sample Type, Adjustable Temperature Settings, Convenient Database Backup & Recovery, and Enhanced Password Protection.  The system measures the rate and extent of aggregation, agglutination, activation and inhibition reactions. Comprehensive results include primary aggregation and slope, secondary aggregation and slope, area under the curve, lag phase, disaggregation and maximum aggregation. The PAP-8E is designed to support diagnoses of hemostasis disorders including von Willebrand Disease (vWD), Glanzmann’s disease, HIT, Bernard Soulier Syndrome, and Sticky Platelet Syndrome as well as to precisely monitor the use of anti-platelet drugs during clinical trials or patient therapy.

For more information: www.biodatacorp.com
E-Mail: customer.service@biodatacorp.com
Read more

prod3

SignaLOCK™ ChemiWestern Kits – Head and Shoulders Above the Rest

KPL offers next-generation solutions to improve sensitivity and time to results in Western blotting applications. New SignaLOCK™ HRP ChemiWestern Kit (Imager), SignaLOCK HRP ChemiWestern Kit (Film), and SignaLOCK AP ChemiWestern Kit (Film/Imager) enable researchers to reach the highest levels of detection sensitivity. These kits enable detection in the nanogram range with only a 1-minute exposure. A longer exposure offers sensitivity in the femtogram range. The high sensitivity of SignaLOCK kits allows you to use primary and secondary antibodies at higher dilutions, minimizing background and lowering cost. They combine a chemiluminescent substrate with a unique non-protein blocker and wash solution in one powerful system. Whether you prefer peroxidase or phosphatase detection, film or imager analysis, SignaLOCK kits enable researchers to see more signal with less background in their Western blots. All kits offer comprehensive protocols and can be used with both nitrocellulose and PVDF membrane.
Read more

ProADM Product News 01

ProADM proven to be the best risk predictor

The new biomarker ProADM significantly improves risk assessment of patients suffering from lower respiratory tract infection (LRTI)

An early risk assessment of LRTI patients is essential for optimizing treatment and rational resource allocation. Adrenomedullin (ADM) has a significant presence in the course of LRTI and is strongly associated with a patient’s risk of mortality and severe complications. ADM reflects a patient’s risk profile while its elevation is independent of the LRTI etiology.
A robust method to assess ADM levels is the measurement of a stable surrogate marker, the mid-regional fragment of ProAdrenomedullin (MR-proADM). The only available automated immunoassay is from Thermo Fisher Scientific.

Features of ProADM (MR-proADM) measurement
• Directly reflective of ADM production in a 1:1 ratio
• Increased stability relative to ADM
• Reliably measurable with the automated Thermo Scientific B·R·A·H·M·S MR-proADM KRYPTOR immunoassay
• Well documented for clinical use
• Rapidly available to aid timely clinical decision-making (assay incubation time 29 minutes)
• Small sample volume (26µL)
• Measurement in EDTA plasma 

>> read more on www.thermoscientific.com/ProAdrenomedullin