C265b GlobeScientific GlobeGlassTubes

Borosilicate glass culture tubes

     
Globe Scientific introduces a new line of high quality borosilicate glass culture tubes. The tubes feature well-rounded bottoms and smooth, fire-polished rims. They are neatly packaged in heavy duty boxes of 250 and shrink wrapped to keep them particle free. The boxes are compact and fit into most test tube dispensers.
    
Read more

ELISA for active form of vitamin B12

Current front-line biochemical tests for assessment of Vitamin B12 status suffer from several important limitations including both false positives and false negatives, a wide indeterminate range and measurement of both active and inactive B12. Hematological test results can also be non-specific or misleading. The Active-B12 assay from Axis-Shield provides an innovative and highly accurate method for assessing Vitamin B12 status. The assay measures holotranscobalamin, the bio-active form of the vitamin. Holotranscobalamin represents only 10-30% of circulating B12 but is the only form taken up and utilized by the cells of the body – the Active-B12 assay therefore gives a more accurate assessment of the body’s B12 status. The CE-marked Active-B12 assay is a standard 96-well ELISA with break-apart strips and is supplied with all required reagents, calibrators and controls. The kit is compatible with liquid- handling automated instruments for higher throughput.
Read more

C306 Mindray

Body fluid analysis with hematology instrument

Equipped with the unique SF-Cube technology (laser scatter, fluorescence plus 3D cell analysis), the BC-6800 hematology analyser provides not only the routine parameters such as WBC 5-part diff, RET and NRBC, but also brings more information such as immature granulocyte, blast, atypical lymphocyte, infected RBC (infected by plasmodium parasite), etc. With a processing throughput of 125 tests per hour, it is also suitable for laboratories with large daily sample loads. The BC-6800 now comes with a new feature, body fluid analysis. The instrument can analyse CSF, pleural, peritoneal fluid samples, as well as provide reportable data for RBC, WBC, WBC differential (polymorphonuclear & mononuclear) and a total cell count (TCBF) on these body fluid samples. Moreover, for research use only, the instrument can give additional WBC differential results for neutrophil and eosinophil. HF-BF is an additional, for research use parameter, which represents high fluorescent cells. High fluorescent cells may contain histiocytes, epithelial cells, spleen cells, exfoliated cells, etc. These cells can bring more clinical information for diagnosis.
Read more

C314 Trinity

HSV-2 IgG immunoassay

Trinity Biotech’s Uni-GoldTM HSV-2 Rapid is a single use immunoassay for the qualititative detection of human IgG class antibodies to HSV-2 in human whole blood (venous or capillary) or serum. This product is the newest addition to the Uni-GoldTM range of STD rapid tests. This easy to use test features a 2 step procedure, giving results within 15 minutes. Used as a frontline screening assay, the Uni-GoldTM HSV-2 Rapid complements the company’s confirmatory CaptiaTM HSV Type Specific ELISA assays. The Uni-GoldTM HSV-2 Rapid will ensure communities and STD clinics can detect HSV-2 faster and more accurately at Point-Of-Impact. The HSV-2 test now joins Trinity’s established HIV test as part of the Uni-GoldTM brand of Point-Of-Impact rapid tests.
Read more

seracare logo

Anti-dengue performance panel

The first commercially available Anti-Dengue Mixed Titer Performance Panel has been launched by SeraCare. It is designed to help blood donor collection facilities, diagnostics manufacturers and clinical laboratories evaluate and troubleshoot their anti-dengue virus assays. The new performance panel is derived from undiluted, unpreserved human plasma specimens, with 21 members representing a wide range of reactivity for anti-dengue IgM and IgG antibodies, from negative to strongly positive. Panel members include samples from individuals with recent and past infection by all four dengue viruses (DENV-1 through DENV-4).
Read more

C269 Belart

Fast and accurate colony counting

Even with the advances in automated and robotic colony counters, there still remains a need for accurate, simple to use and lower cost hand-held units. The efficient and accurate handheld Scienceware Colony Counter is ideal for those who only do counting on an irregular basis or only count a few plates at a time and do not wish the expense of investing space and capital in a larger system. Simple to operate, the unit marks, counts and gives an audible and visual alert each time a count is registered on the digital display. The lightweight, comfortable to hold, pen-style design reduces the likelihood of error, combining all aspects of counting into one motion. Error is further reduced by the ability to count both up and down to verify sample counts. Able to store up to 35 sample counts in its memory, it can also display the sum total of all colonies counted. The display has a backlight for easy viewing in low light conditions, the audible alert can be turned off if desired, and the counting function can be locked to prevent error during breaks between counting. Long-life, red and black felt-tip markers, a protective storage case and a 3V lithium battery are included. A complete counting system that includes the colony counter, a magnifier, light box, AC adapter, and counting grid is also available.
Read more

C301 DiagnosticaStago

HIT diagnostic test

Patients with Heparin Induced Thrombocytopenia (HIT) have a very high thrombosis risk. They require alternative anticoagulant treatments which increase the bleeding risk. In the absence of a rapid and reliable laboratory assay, many clinicians simply replace heparin based on clinical suspicion only. However, only about 10% of HIT suspicions are actually confirmed by appropriate tests. Current immunoassays can rule out HIT but have limitations, especially a high number of false positive tests, long time to result, complex handling, and reagent wastage. The STic Expert® HIT kits match all laboratory requirements, including reliability (100% Negative Predictive Value), which rules out HIT when combined with the pretest clinical score, and 93% specificity, which reduces false positive results and the number of confirmatory tests required. Results are available in 10 minutes. Easy and ready to use, the unitary test is available 24/7 STAT compliant for laboratories of all sizes. It reduces the cost of HIT outsourcing and eliminates the need for extra equipment. Two packaging sizes are available, 5 tests per kit and 20 tests per kit, with individual tests in blister packs.
Read more

C312 Vedalab

Qualitative and quantitative hCG test

Vedalab’s new rapid test, h-CG-Check-1, is available in two versions: qualitative (for visual reading) or quantitative (for use with the Easy Reader instrument). The test has been specifically designed for the detection of human chorionic gonadotropin in whole blood, plasma or serum (using only 25μL of serum/plasma or 50μL of blood). Results are obtained within 5 to 10 minutes. These qualitative and quantitative rapid tests are particularly useful when examining injured women admitted to hospital emergency wards as they allow the practitioner to determine, in a very short time, whether or not the patient is pregnant so that medical care can be adapted accordingly.
Read more

C305 Coris

C. difficile GDH detection

Clostridium difficile is an anaerobic bacteria that grows in the intestine when the normal flora has been altered by treatment with antibiotics. Only toxigenic strains cause infections from mild-diarrhea to pseudomembranous colitis, potentially leading to death. Detection of Glutamate Dehydrogenase (GDH) that is an antigen marker of C.difficile proliferation allows significant cost reduction in lab diagnosis for suspected C.difficile samples. Positive GDH samples should be investigated further to test for the toxins A or/and B. The Coris C. diff-Strip is a ready-to-use immunochromatographic test that allows the specific detection of C.difficile GDH in stool specimens in a strip format. When the fecal suspension comes into contact with the strip, the solubilized conjugate migrates with the sample and both reagents come into contact with the anti-Clostridium GDH antibody adsorbed onto the nitrocellulose. If the sample contains C.difficile GDH, a red line develops. The result is visible within 15 minutes.
Read more

C299 Samsung LABGEO IB10

Point of care analyser

LABGEO IB10 is a quantitative 1-step immunoassay system for point of care testing using centrifugal microfluidics. Compact and lightweight (177 x 330 x 177 mm, 2.4kg), the instrument provides outstanding battery-powered portability that makes it easier and quicker to use in moving ambulances and emergencies. This analyser tests multiple cardiac and infectious disease parameters, and delivers test results within 20 minutes.
Read more