Nova blood gas analysers add important new test – estimated plasma volume

Nova Biomedical has added a key new test to its Stat Profile Prime Plus critical care analyser – the ability to calculate and report estimated plasma volume (ePV), a very important test for critically ill patients but one that has been very difficult to obtain. The plasma volume status of a patient is one of the top priorities in evaluating and treating many different conditions including, shock, sepsis, congestive heart failure, acute or chronic kidney disease, chronic pulmonary disease, as well as general postoperative care.

Plasma volume is the amount of intravascular fluid minus red blood cells, white blood cells, and platelets. Timely, accurate measurement of plasma volume or overall volume status has been notoriously difficult if not impossible. Thus, many surrogates for volume status have been developed over the years, from simple non-invasive measures such as patient history and physical examination, weight, laboratory studies, and radiographic imaging, to more complex and invasive techniques such as CVP or pulmonary capillary wedge pressure measurement. More recently other noninvasive or minimally invasive techniques have been developed but they are costly, cumbersome and cannot be adapted to the most important clinical need – serial measurements over time.

Several formulas based on haemoglobin, haematocrit, and sometimes weight were developed decades ago, and have recently been studied in various patient populations with some promising results. One of the more commonly used formulas is the Strauss equation, which requires measured haemoglobin and measured haematocrit to determine ePV. Calculated haematocrit or haemoglobin can produce inaccurate results in patients who have abnormal red blood cell size and patients who are experiencing rapid fluid shifts. Elevated ePV has been shown to be an independent predictor of all-cause mortality. ePV seems to be most beneficial when it is measured serially, and thus the change in plasma volume (ΔPV) can be gauged. This has been shown to have prognostic ability in patients with heart failure and there is intense interest in its usefulness in sepsis, dialysis, postoperative care, dengue, and other conditions.

The Stat Profile Prime Plus analyser has both measured haemoglobin and measured haematocrit (along with blood gases, electrolytes, metabolites, and co-oximetry), and is uniquely capable of reporting ePV using the Strauss equation. The Prime Plus performs the Strauss ePV calculation and provides both trend data and delta values. With the addition of ePV, Prime Plus helps clinicians assess patient intravascular volume, acid base balance, blood oxygenation, oxygen carrying capacity of blood, tissue hypoxia, electrolyte balance, kidney function, and glucose control in one minute from two drops of blood.

For more information, visit: novabiomedical.com