Direct thrombin inhibitor assays
We have investigated the effects of three (Lepirudin, Argatroban and Bivalirudin) direct thrombin inhibitors (DTI) on routine and dedicated assays. We found routine tests to be non-discriminative between concentrations of different DTI. The dedicated Hemoclot assay showed identical lineair increases for all three DTI. We conclude that a dedicated calibrated assay based on a diluted […]