New insights into how the colon functions and actually expels its contents have been revealed for the first time following decades of study by Flinders University researchers.
It promises new diagnostics tools and treatments for gastrointestinal disorders to address problems with bowel movements leading to constipation, diarrhoea and pain, affecting hundreds of millions of people worldwide.
Propulsion of intestinal contents is controlled by millions of neurons within the wall of the gut, known as the enteric nervous system. Capable of operating independently of the brain, a functioning enteric nervous system is essential for life – but exactly how it functions has been a mystery.
By unravelling the neural circuits of the enteric nervous system in guinea pigs and humans Professor Marcello Costa and colleagues are able to understand how the enteric nervous system ensures that food is slowly mixed and propelled along the digestive tube, allowing for absorption of nutrients and excretion of waste.
“For the first time we have combined video recording intestinal movements with a pressure-measuring manometric probe, enabling movements, pressures and electrical activities to be recorded all at the same time within the colon.
“This powerful combination of techniques applied to a guinea pig colon identified several distinct neural mechanisms involved in the propulsion of colonic contents.
“This answers the deceptively simple question of how neural mechanisms within the colon manage the propulsion of bowel contents” Professor Costa says.
“The findings also show how studies in human and animals can be complementary, identifying fundamental mechanisms that are shared across species – in this case guinea pigs and humans. “Currently we treat intestinal disorders by addressing the symptoms, such a stopping-up diarrhoea or softening stools to ease constipation, but as a result of this new understanding of the neural networks of the enteric system, clinicians may be able to develop treatments that treat the cause of the problems” Professor Costa says.
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:07:59Cracking the colon code – new light shed on gut function
A new type of blood test for breast cancer could help avoid thousands of unnecessary surgeries and otherwise precisely monitor disease progression, according to a study led by the Translational Genomics Research Institute (TGen) and Mayo Clinic in Arizona.
The study suggests that the test called TARDIS — TARgeted DIgital Sequencing — is as much as 100 times more sensitive than other blood-based cancer monitoring tests.
TARDIS is a “liquid biopsy” that specifically identifies and quantifies small fragments of cancer DNA circulating in the patient’s bloodstream, known as circulating tumour DNA (ctDNA). According to the study, TARDIS detected ctDNA in as low as 2 parts per 100,000 in patient blood.
“By precisely measuring ctDNA, this test can detect the presence of residual cancer, and inform physicians if cancer has been successfully eradicated by treatment,” said Muhammed Murtaza, M.B.B.S., Ph.D., Assistant Professor and Co-Director of TGen’s Center for Noninvasive Diagnostics. He also holds a joint appointment on the Research Faculty at Mayo Clinic in Arizona, and is one of the study’s senior authors.
For example, Dr. Murtaza explained, TARDIS is precise enough to tell if early stage breast cancer patients have responded well to pre-operative drug therapy. It is more sensitive than the current method of determining response to drug therapy using imaging.
“This has enormous implications for women with breast cancer. This test could help plan the timing and extent of surgical resection and radiation therapy after patients have received pre-operative therapy,” said Dr. Barbara A. Pockaj, M.D., a surgical oncologist who specializes in breast and melanoma cancer patients at Mayo Clinic in Arizona, and is the study’s other senior author. Dr. Pockaj is the Michael M. Eisenberg professor of surgery and the chair of the Breast Cancer Interest Group (BIG), a collaboration between researchers at Mayo, TGen and ASU.
Unlike traditional biopsies, which only produce results from one place at one time, liquid biopsies use a simple blood draw, and so could safely be performed repeatedly, as often as needed, to detect a patient’s disease status.
“TARDIS is a game changer for response monitoring and residual disease detection in early breast cancer treated with curative intent. The sensitivity and specificity of patient-specific TARDIS panels will allow us to tell very early, probably after one cycle, whether neo-adjuvant (before surgery) therapy is working and will also enable detecting micro-metastatic disease and risk-adapted treatment after completing neo-adjuvant therapy,” said Dr. Caldas, who also is Senior Group Leader at the Cancer Research UK Cambridge Institute, and one of the study’s contributing authors.
Following further clinical testing and trials, TARDIS could someday be routinely used for monitoring patients during cancer treatment, and discovering when patients are essentially cured and cancer free.
“The results of these tests could be used to individualize cancer therapy avoiding overtreatment in some cases and under treatment in others,” Dr. Murtaza said. “The central premise of our research is whether we can develop a blood test that can tell patients who have been completely cured apart from patients who have residual disease. We wondered whether we can see clearance of ctDNA from blood in patients who respond well to pre-surgical treatment.”
Current tests and imaging lack the sensitivity needed to make this determination.
“Fragments of ctDNA shed into blood by tumours carry the same cancer-specific mutations as the tumour cells, giving us a way to measure the tumour,” said Bradon McDonald, a computational scientist in Dr. Murtaza’s lab, and the study’s first author.
“The problem is that ctDNA levels can be so low in non-metastatic cancer patients, there are often just not enough fragments of ctDNA in a single blood sample to reliably detect any one mutation. This is especially true in the residual disease setting, when there is no obvious tumour left during or after treatment,” McDonald said. “So, instead of focusing on a single mutation from every patient, we decided to integrate the results of dozens of mutations from each patient.”
Translational Genomics Research Institutewww.tgen.org/news/2019/august/07/new-ctdna-blood-test-for-cancer/
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:08:03Liquid biopsy blood test improves breast cancer diagnostics
Japanese scientists report a new method to construct 3D models from 2D images. The approach, which involves non-rigid registration with a blending of rigid transforms, overcomes several of the limitations in current methods. The researchers validate their method by applying it to the Kyoto Collection of Human Embryos and Fetuses, the largest collection of human embryos in the world, with over 45,000 specimens.
MRI and CT scans are standard techniques for acquiring 3D images of the body. These modalities can trace with unprecedented precision the location of an injury or stroke. They can even reveal the microscopic protein deposits seen in brain pathologies like Alzheimer’s disease. However, for the best resolution, scientists still depend on slices of the specimen, which is why cancer and other biopsies are taken. Once the information desired is acquired, scientists use algorithms that can put together the 2D slices to recreate a simulated 3D image. In this way, they can reconstruct an entire organ or even organism.
Stacking slices together to create a 3D image is akin to putting a cake together after it has been cut. Yes, the general shape is there, but the knife will cause certain slices to break so that the reconstructed cake never looks as beautiful as the original. While this might not upset the party of five-year olds who want to indulge, the party of surgeons looking for the precise location of a tumour are harder to appease.
“The sectioning process stretches, bends and tears the tissue. The staining process varies between samples. And the fixation process causes tissue destruction,” explains Nara Institute of Science and Technology (NAIST), Nara, Japan, Associate Professor Takuya Funatomi, who led the project. Fundamentally, there are three challenges that emerge with the 3D reconstruction. First is non-rigid deformation, in which the position and orientation of various points in the original specimen have changed. Second is tissue discontinuity, where gaps may appear in the reconstruction if the registration fails. Finally, there is a scale change, where portions of the reconstruction are disproportional to their real size due to non-rigid registration.
For each of these problems, Associate Professor Takuya Funatomi and his research team proposed a solution that when combined resulted in a reconstruction that minimizes all three factors using less computational cost than standard methods.
“First, we represent non-rigid deformation using a small number of control points by blending rigid transforms,” says Funatomi. The small number of control points can be estimated robustly against the staining variation.
“Then we select the target images according to the non-rigid registration results and apply scale adjustment,” he continues.
The new method mainly focuses on a number of serial section images of human embryos from the Kyoto Collection of Human Embryos and Fetuses and could reconstruct 3D embryos with extraordinary success.
Notably, there are no MRI or CT scans of the samples, meaning no 3D models could be used as a reference for the 3D reconstruction. Further, wide variability in tissue damage and staining complicated the reconstruction.
Nara Institute of Science and Technology
https://tinyurl.com/y4ealgow
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:08:10Reconstructing histological slices into 3D images
by Dr Ann-Christin Niehoff Multimodal imaging by mass spectrometry offers a spatially resolved analysis of tissue sections as an additional tool in clinical research. Here, matrix-assisted laser desorption/ionization mass spectrometry for molecular imaging and laser ablation inductively coupled plasma mass spectrometry for elemental imaging are used to tackle two drug applications. Mass spectrometry imaging In recent years, mass spectrometry imaging (MSI) has gained more and more interest in the field of clinical, biological and pharmaceutical research. In contrast to hyphenated chromatographic techniques (e.g. LC-MS or GC-MS), MSI provides spatially resolved information while maintaining high sensitivity. With today’s techniques, high spatial resolution down to the low micrometre range can be achieved and is therefore a good combination with existing clinical imaging approaches from pathology.
Multimodal imaging describes the combination of different imaging techniques, as none by itself is a gold standard to answer all questions. Since MSI works with tissue sections, it can be combined easily with various microscopy applications, providing an additional input to clinical histology. Although protocols for different kinds of tissue sections exist, the preference here is to work on cryosections rather than formalin-fixed paraffin-embedded sections; this helps to avoid wash out of analytes from the tissue during the fixation and embedding steps.
Different MSI techniques can be used to focus on molecular or elemental imaging. In this article, the focus will be on matrixassisted laser desorption ionization mass spectrometry (MALDIMS) for molecular and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for elemental imaging. MALDI-MSI MALDI-MS is the most frequently used imaging technique in molecular MS. The analysis requires coating of the tissue section with a matrix, typically a small organic compound, and performing soft ionization of desorbed molecules by a pulsed laser. Ionization efficiency is highly dependent on molecular structure, matrices and laser wavelength. By scanning over the sample, a full mass spectrum is generated for each pixel.
Using the tandem MS (MS/MS) mode, fragmentation studies can provide information on molecular structures. Matrix preparation is one of the critical aspects and a potential disadvantage of MALDI-MS, Microscopy and Imaging in the Clinical Lab June 2020 21 | Figure1. Multimodal imaging of myocardial infarction Microscopic images of the two parallel sections (a & b) with the area of myocardial infarct (marked with a black line), quantified distribution of gadolinium determined with LA-ICP-MS (c) at 15|μm spot size, distribution of the ligand from Gadofluorine P (d) at 40|μm spot size, as well as the structure of the ligand and the theoretical spectrum (cyan bars) and the measured spectra (black line) with MALDI-MS (e). as it may influence limits of detection and spatial resolution due to analyte extraction of the sample by the matrix. Different instruments for matrix preparation are therefore commercially available to improve homogenous distribution and reproducibility. Owing to matrix effects in molecular MS, quantification is challenging, but is possible to achieve for single analytes via internal standards or standard addition with matrix matched standards.
Here, matrix was sublimated using the iMLayer (Shimadzu). MALDI-MS experiments were performed with the iMScope TRIO (Shimadzu), equipped with a fluorescence microscope, atmospheric pressure MALDI-source and an ion trap/time-of-flight (IT-TOF) mass analyser. IMAGEREVEAL MS (Shimadzu) was used for data analysis. LA-ICP-MSI In the field of elemental MSI, LA-ICP-MS provides major, minor and trace elemental information on surfaces and tissue sections. A laser is scanned over the sample and the ablated material is transported by a carrier gas into the ICP source, where the particles are atomized and ionized. To obtain spatially resolved images, transient signals of the respective analyte are required.
As mass analyser, quadrupoles are most frequently used. Although less matrix dependent than MALDI-MS, a fundamental aspect of recent research is method development for reliable quantification strategies, mainly via matrix matched standards. The major disadvantages of LA-ICP-MS are its destructive nature with loss of molecular information.
In this study, experiments were performed with the LSX-G2+ laser ablation system (Teledyne Cetac Technologies) coupled to the quadrupole based ICPMS-2030 (Shimadzu). Complementary bioimaging of Gadofluorine P in myocardial infarction in mice Magnetic resonance imaging is a widely used imaging technique in daily clinical practice. To enhance contrast during this examination, several different contrast agents are available. While most gadoliniumbased contrast agents (GBCAs) distribute systemically, some targetspecific GBCAs are under investigation as well. Gadofluorine P is one of these target-specific contrast agents and shows high affinity towards the collagen-rich extracellular matrix which is secreted in the event of myocardial infarction (MI) [1].
In this application, mice underwent injection of Gadofluorine P solution as contrast agents 6|weeks after an induced MI. Afterwards the mice were sacrificed and the hearts were removed for cryosections preparation. By multimodal imaging, LA-ICP-MS was used to generate quantified elemental imaging of gadolinium, while MALDI-MS validated the findings (Fig. 1) and could further provide information for phospholipids and heme b distribution (data not shown).
Figure 1 shows the microscopic images (a & b) of the two thin sections analysed. With LA-ICP-MS (c), a homogeneous distribution of the gadolinium in the healthy myocardium with an average concentration of about 50|μg/g was detected. The infarct region contained two times higher gadolinium concentrations of about 110|μg/g with maximum values up to 370|μg/g.
Higher gadolinium concentrations could also be found in the ventricle due to the intravenous administration of the contrast agent. These distributions could be verified with MALDI-MS imaging (d).
In this experiment, only the protonated ligand of Gadofluorine P rather than the intact complex could be detected (e). The main peak (m/z 1168.39) was used to create the image, which showed good correlation to the gadolinium distribution determined with LA-ICP-MS. The highest intensities of the molecular probe were found in MI and ventricle regions, whereas healthy myocardium showed low and homogenous intensities. Multimodal imaging of photosensitizers in 3D tumour cell models Photodynamic therapy offers an alternative cancer treatment. A photosensitive compound (photosensitizer; PS) is administered and the tumour is subsequently irradiated. The activation of the PS leads to the formation of a reactive oxygen species and subsequently to cell apoptosis. One main challenge in the development of PS is the hydrophobic character of the compounds, which hinders tissue penetration. Additionally, the orally administered compound needs to pass through the mucus layer in the gastrointestinal tract. Thus, the determination of the penetration depth of these compounds is of great interest.
The use of 3D tumour spheroids enables in vitro drug screening, while simulating the tumour environment better than 2D cell cultures. The photosensitizer 5,10,15,20-tetrakis (3-hydroxy-phenyl)-porphyrin (mTHPP) and its palladiumtagged analogue mTHPP-Pd were analysed in this study. Here, multimodal imaging is used to visualize the penetration depth of mTHPP and the lipid distribution in 3D tumour spheroid by MALDI-MS (5|μm spot size) as well as to quantify the drug by LA-ICP-MS (7|μm spot size) [2,3].
The MALDI-MS and LA-ICP-MS images of a tumour spheroid treated with mTHPP or mTHPP-Pd are shown in Figure 2. In the microscopic image, an almost spherical tissue section with a diameter of approx. 550|μm can be seen. The distribution map of mTHPP shows a ring-shaped distribution, which can be precisely correlated with the outer cell layer of the tumour spheroid. The PS is distributed homogeneously inside the outer layer and not around the spheroid, although it does not penetrate deeper into the tissue.
Nevertheless, the MALDI-MS experiments revealed that the PS can be detected as an intact molecule without substantial decomposition during the sample preparation. The LA-ICP-MS results for a spheroid incubated with mTHPP-Pd show the same distribution as the mTHPP detected by MALDI-MS. Since the metal-tagged PS is needed for ICP-MS analysis, only spheroids treated with this compound could be investigated. Conversely, this modification of the molecule could no longer be detected using MALDI-MS. Owing to the loading with palladium, the preferred protonation sites of the molecule are unavailable, impairing the detection.
However, before LA-ICP-MS experiments, MALDI-MS can be used to identify phospholipids as shown in Figure 3. Palladium concentrations up to 10|μg/g with an average of 1.9|μg/g were detected (Fig. 3b). This represents an enrichment of PS by a factor of 3 (average) up to 18 (highest concentration) compared to the incubation concentration. The phospholipids PC(34:1), PC(34:0) and PC(30:0) could be detected and show different distributions coherent with the different metabolic zones in a tumour spheroid. Conclusion In conclusion, the two applications shown provide an example of how to add MSI to clinical research. Multimodal imaging has successfully been performed to address drug penetration and enrichment in different kinds of tissue based on the combination of elemental imaging and molecular imaging by LA-ICP-MS and MALDI-MS. The author Ann-Christin Niehoff PhD European Innovation Center, Shimadzu Europa GmbH, 47259 Duisburg, Germany
E-mail: acn@shimadzu.eu
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:07:48Advantages of multimodal imaging by elemental and molecular mass spectrometry
by Dr Huub H. van Rossum Recently, significant improvements have been made in understanding and applying moving average quality control (MA QC) that enable its practical implementation. These include the description of new and laboratory-specific MA QC optimization and validation methods, the online availability thereof, insights into operational requirements, and demonstration of practical implementation. Introduction Moving average quality control (MA QC) is the process of algorithmically averaging obtained test results and using that average for (analytical) quality control purposes. MA QC is generally referred to as patient-based real-time quality control (PBRTQC) because it is one of various methods (e.g. limit checks, delta checks, etc) that use patient results for (real-time) quality control. MA QC was first described over half a century ago as ‘average of normals’ [1]. Since then, it has evolved into a more general MA QC concept not necessarily based on using mean calculations of the obtained ‘normal’ test results [2]. Although MA QC has been available for a few decades, its adoption by laboratories has been limited due to the complexity of setting up the necessary procedures, operational challenges and a lack of evidence to justify its application and demonstrate its value. During the past 5|years, however, significant improvements have been made in the field of MA QC, and research studies have addressed all these issues. Consequently, true practical application of validated MA QC procedures to support analytical quality control in medical laboratories is now possible. Furthermore, the recent improvements may well change the way we perform daily analytical quality control in medical laboratories in the near future. MA QC optimization and validation The recent significant improvements in the field of MA QC include, first and foremost, the description of new methods to design and optimize laboratory-specific MA QC procedures and to enable validation of their actual error-detection performance [2–5]. These methods use realistic MA QC simulations based on laboratory-specific datasets and thus provide objective insights into MA QC error detection [2]. To enable practical implementation, the requirement that the number of MA QC alarms must be manageable is now acknowledged as essential and has been fulfilled when setting up MA QC [2, 6]. The newly developed methods use a novel metric to determine the error-detection performance: that is, the mean or median number of test results needed for error detection. One of the new methods presents these simulation results in bias-detection curves so that the optimal MA QC procedure can be selected, based on its overall error-detection performance [5]. An example of a bias-detection curve and its application is presented in Figure 1. After selecting the optimal MA QC settings, an MA validation chart can be used to obtain objective insights into the overall error-detection performance and the uncertainty thereof. Therefore, this chart can be seen as a validation of the MA QC procedure. An example of an MA validation chart is presented in Figure 2 and shows that the MA QC procedure will almost always (with 97.5% probability) detect a systematic error of −4% (or larger negative errors) within 20 test results.
Importantly, this method has become available to laboratories via the online MA Generator application, enabling them to design their own optimized and validated MA QC procedures [7]. Laboratories can now upload their own datasets of historical results, study potential MA QC settings using this simulation analysis and obtain their own laboratory-specific MA QC settings and MA validation charts. Several laboratories have demonstrated that this tool has enabled them to obtain relevant MA QC settings and thus implement MA QC [8, 9]. Integration of MA QC with internal QC Measurement of internal quality control (iQC) samples is still the cornerstone of analytical quality control as performed in medical laboratories. For many tests, iQC alone is sufficient to assure and control the quality of obtained test results. For some tests, however, iQC itself is insufficient. The reasons for this are related to certain fundamental characteristics of iQC that include: lack of available (stable) control materials, its scheduled character, the risk of using non-commutable control samples and tests with a sigma metric score of ≤4. For several reasons, PBRTQC or, more specifically, MA QC is a particularly valuable and powerful way to support quality assurance in such cases.
First, if no (stable) QC materials are available it is impossible, or it becomes complicated, to use iQC. This is, for example, relevant for the erythrocyte sedimentation rate, serum indices or hemocytometry tests including erythrocyte mean corpuscular volume in particular. MA QC is possible as long as patient results are available. Second, the scheduled character of iQC becomes a limitation and a risk when temporary assay failures or rapid onset of critical errors occur between scheduled iQC. Because a new MA QC value can be calculated for each newly obtained test result, MA QC can be designed as a continuous and real-time QC tool. In this context, detection of temporary assay failure by MA QC between scheduled iQC has been demonstrated for a sodium case [10], and several examples of MA QC detection of rapid onset of critical errors have been published for both chemistry and hematological tests [11]. Third, because PBRTQC methods such as MA QC use obtained patient results, by design there is no commutability issue. Fourth, and finally, for some tests iQC is intrinsically limited in its ability to detect relevant clinical errors, due to the low ratio of biological variations to analytical variations, as reflected in low sigma metric values. Such tests require frequent iQC analysis and application of stringent control rules. However, even with such an intensive and strict iQC set-up, the probability of detecting clinically relevant errors remains limited [12]. In contrast, MA QC has the best error-detection performance for tests with a low sigma value [13].
For all these reasons, MA QC is ideal for supplementing analytical quality control by iQC. Recently, an approach was presented that integrated MA QC into the QC plan when iQC was found to be insufficient [9]. This approach was based on first determining whether one of the abovementioned iQC limitations applied to a test. If so, then iQC alone was considered insufficient and MA QC was studied, using the online MA Generator tool (www.huvaros.com) to obtain optimal MA QC settings and MA QC procedures to support the analytical quality control [7, 9]. The MA QC error-detection performance was validated using MA validation charts. These latter insights into MA QC error detection also enabled iQC measurements to be reduced. The MA QC procedures alone provided significant error-detection performance, so running iQC measures multiple times a day would add only limited error-detection performance. Therefore, it was decided to run the iQC only once a day and add the obtained MA QC procedures to the QC plan.
Others have taken this a step further and studied MA QC not only for tests with limited iQC performance but also for a much larger test selection, in order to reduce the number of iQC measures and more efficiently schedule and apply iQC [4]. This approach has been shown to be successful for a large commercial laboratory with high production numbers. Since the MA QC error-detection performance improves with an increasing number of test results and benefits from a small number of pathological test results, this approach may be particularly valuable to the larger commercial laboratories. For such an approach, the key is objective insights into the error-detection performance of MA QC procedures such as obtained using MA validation charts. Implementation and application of MA QC for real-time QC in medical laboratories The final aspect in which there have been significant improvements in recent years relates to the practical application of MA QC in medical laboratories. Recently, an International Federation of Clinical Chemistry and Laboratory Medicine working group was founded that summarized medical laboratories’ experiences of practically applying MA QC and formulated several recommendations for both MA QC software suppliers and medical laboratories that are working on, or are interested in, implementation of MA QC [14, 15]. Also, a step-by-step roadmap has recently been published to enable MA QC implementation [9]. The first two steps of this roadmap – i.e. selection of tests and obtaining MA QC settings for them – were discussed in the previous two paragraphs.
The next step would be to set up and configure the software used to implement MA QC in medical laboratories. If you are interested in applying MA QC in your laboratory, it is important to review the available software (e.g. analyser, middleware, LIS, third party) and to decide which will be used to run and apply MA QC. Your decision depends not only on the availability of suitable software in or for the laboratory, but also on the actual MA QC functionality present in the software packages.
The minimum software features that are necessary to enable practical implementation have been formulated [2, 15]. In my view, key elements would be that the software supports: exclusion of specified samples (non-patient materials, QC results, extreme results, etc), calculation of relevant MA QC algorithms, applying SD-based as well as non-statistical control limits (plain lower and upper control limits), proper real-time alarming and – depending on the MA QC optimization method – presentation of MA QC in a Levey–Jennings or accuracy graph. Figure 3 presents an example of MA QC in an accuracy graph as operated for real-time QC in my laboratory. To enable effective implementation of MA QC, all of these software features should be configured.
The final implementation step I wish to address here is the design of laboratory protocols for working up MA QC alarms, which determines the extent to which an error detected by an MA QC alarm is acknowledged. An important requirement is that all MA QC alarms should be worked up by means of this protocol.
As previously indicated, because MA QC can generate many more QC results and alarms than iQC, a critical requirement of every MA QC procedure is a manageable number of alarms. As a result, when an MA QC alarm occurs there is a reasonable chance of detecting error.
A first common action as part of the MA QC alarm protocol would be to run iQC. This provides a quick insight into the size of the error and enables rapid confirmation of large errors. As a second step, re-running of recently analysed samples (in addition to running iQC) enables temporary assay failures to be detected and can confirm or exclude errors not necessarily detectable by iQC. Also, finally, a review of recently analysed test results to identify a pre-analytical cause or a single patient with extreme but valid test results is often very useful as part of the MA QC alarm protocol. All these aspects have recently been discussed in greater detail [10, 14]. Conclusions Altogether, the recent developments in the field of PBRTQC and, more specifically, MA QC now – finally – enable true practical implementation of MA QC in medical laboratories and allow more effective and efficient QC plans to be designed. The authors Huub H. van Rossum1,2 PhD 1 Department of Laboratory Medicine, The Netherlands Cancer Institute, Amsterdam, The Netherlands 2 Huvaros, Amsterdam, The Netherlands
E-mail: h.v.rossum@nki.nl
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:07:52Consider moving average quality control when internal control is insufficient or inefficient – the time is now!
The new coronavirus, SARS-CoV-2, causing a disease that has been called COVID-19, was first identified in Wuhan, China in December 2019, and has been transmitted widely across the globe. This article gives a general overview of what is currently known in a fast developing situation.
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:07:56COVID-19: a global pandemic
Working with model mice, post-mortem human brains, and people with schizophrenia, researchers at the RIKEN Center for Brain Science in Japan have discovered that a subtype of schizophrenia is related to abnormally high levels hydrogen sulfide in the brain.
Experiments showed that this abnormality likely results from a DNA-modifying reaction during development that lasts throughout life. In addition to providing a new direction for research into drug therapies, higher than normal levels of the hydrogen sulfide-producing enzyme can act as biomarker for this type of schizophrenia.
Diagnosing disorders of thought is easier when a reliable and objective marker can be found. In the case of schizophrenia, we have known for more than 30 years that it is associated with an abnormal startle response. Normally, we are not startled as much by a burst of noise if a smaller burst – called a prepulse – comes a little bit earlier. This phenomenon is called prepulse inhibition (PPI) because the early pulse inhibits the startle response. In people with schizophrenia, PPI is lowed, meaning that their startle response is not dampened as much as it should be after the prepulse.
The PPI test is a good behavioural marker, and although it cannot directly help us understand the biology behind schizophrenia, it was the starting point that led to current discoveries.
The researchers at RIKEN CBS began first looked for differences in protein expression between strains of mice that exhibit extremely low or extremely high PPI. Ultimately, they found that the enzyme Mpst was expressed much more in the brains of the mouse strain with low PPI than in the strain with high PPI. Knowing that this enzyme helps produce hydrogen sulfide, the team then measured hydrogen sulfide levels and found that they were higher in the low-PPI mice.
"Nobody has ever thought about a causal link between hydrogen sulfide and schizophrenia," says team leader Takeo Toshikawa. "Once we discovered this, we had to figure out how it happens and if these findings in mice would hold true for people with schizophrenia."
First, to be sure that Mpst was the culprit, the researchers created an Mpst knockout version of the low-PPI mice and showed that their PPI was higher than that in regular low-PPI mice. Thus, reducing the amount of Mpst helped the mice become more normal. Next, they found that MPST gene expression was indeed higher in postmortem brains from people with schizophrenia than in those from unaffected people. MPST protein levels in these brains also correlated well with the severity of premortem symptoms.
Now the team had enough information to look at MPST expression as a biomarker for schizophrenia. They examined hair follicles from more than 150 people with schizophrenia and found that expression of MPST mRNA was much higher than people without schizophrenia. Even though the results were not perfect-indicating that sulfide stress does not account for all cases of schizophrenia-MPST levels in hair could be a good biomarker for schizophrenia before other symptoms appear.
Whether a person develops schizophrenia is related to both their genetics and the environment. Testing in mice and postmortem brains indicated that high MPST levels were associated with changes in DNA that lead to permanently altered gene expression. So, the next step was for the team to search for environmental factors that could result in permanently increased MPST production.
Because hydrogen sulfide can actually protect against inflammatory stress, the group hypothesized that inflammatory stress during early development might be the root cause. "We found that anti-oxidative markers – including the production of hydrogen sulfide – that compensate against oxidative stress and neuroinflammation during brain development were correlated with MPST levels in the brains of people with schizophrenia," says Yoshikawa.
He proposes that once excess hydrogen sulfide production is primed, it persists throughout life due to permanent epigenetic changes to DNA, leading to "sulfide stress" induced schizophrenia.
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:07:59Biomarker for schizophrenia can be detected in human hair
Researchers at Rady Children’s Institute for Genomic Medicine (RCIGM) have utilized automated machine-learning and clinical natural language processing (CNLP) to diagnose rare genetic diseases in record time. This new method is speeding answers to physicians caring for infants in intensive care and opening the door to increased use of genome sequencing as a first-line diagnostic test for babies with cryptic conditions.
“Some people call this artificial intelligence, we call it augmented intelligence,” said Stephen Kingsmore, MD, DSc, President and CEO of RCIGM. “Patient care will always begin and end with the doctor. By harnessing the power of technology, we can quickly and accurately determine the root cause of genetic diseases. We rapidly provide this critical information to intensive care physicians so they can focus on personalizing care for babies who are struggling to survive.”
The workflow and research were led by the RCIGM team in collaboration with leading technology and data-science developers —Alexion, Clinithink, Diploid, Fabric Genomics and Illumina.
Dr. Kingsmore’s team has pioneered a rapid Whole Genome Sequencing process to deliver genetic test results to neonatal and paediatric intensive care (NICU/PICU) physicians to guide medical intervention. RCIGM is the research arm of Rady Children’s Hospital-San Diego.
By reducing the need for labour-intensive manual analysis of genomic data, the supervised automated pipeline provided significant time-savings. In February 2018, the same team achieved the Guinness World Record for fastest diagnosis through whole genome sequencing. Of the automated runs, the fastest times – averaging 19 hours – were achieved using augmented intelligence.
“This is truly pioneering work by the RCIGM team—saving the lives of very sick newborn babies by using AI to rapidly and accurately analyse their whole genome sequence “ says Eric Topol, MD, Professor of Molecular Medicine at Scripps Research and author of the new book Deep Medicine.
RCIGM has optimized and integrated several time-saving technologies into a rapid Whole Genome Sequencing (rWGS) process to screen a child’s entire genetic makeup for thousands of genetic anomalies from a blood sample.
Key components in the rWGS pipeline come from Illumina, the global leader in DNA sequencing, including Nextera DNA Flex library preparation, whole genome sequencing via the NovaSeq 6000 and the S1 flow cell format. Speed and accuracy are enhanced by Illumina’s DRAGEN (Dynamic Read Analysis for GENomics) Bio-IT Platform.
Other pipeline elements include Clinithink’s clinical natural language processing platform CliX ENRICH that quickly combs through a patient’s electronic medical record to automatically extract comprehensive patient phenotype information.
Another core element of the machine learning system is MOON by Diploid. The platform automates genome interpretation using AI to automatically filter and rank likely pathogenic variants. Deep phenotype integration, based on natural language processing of the medical literature, is one of the key features driving this automated interpretation. MOON takes five minutes to suggest the causal mutation out of the 4.5 million variants in a whole genome.
In addition, Alexion’s rare disease and data science expertise enabled the translation of clinical information into a computable format for guided variant interpretation.
As part of this study, the genetic sequencing data was fed into automated computational platforms under the supervision of researchers. For comparison and verification, clinical medical geneticists on the team used Fabric Genomics’ AI-based clinical decision support software, OPAL (now called Fabric Enterprise)—to confirm the output of the automated pipeline. Fabric software is part of RCIGM’s standard analysis and interpretation workflow.
The study titled “Diagnosis of genetic diseases in seriously ill children by rapid whole-genome sequencing and automated phenotyping and interpretation,” found that automated, retrospective diagnoses concurred with expert manual interpretation (97 percent recall, 99 percent precision in 95 children with 97 genetic diseases).
Researchers concluded that genome sequen-cing with automated phenotyping and interpretation—in a median 20:10 hours—may spur use in intensive care units, thereby enabling timely and precise medical care. “Using machine-learning platforms doesn’t replace human experts. Instead it augments their capabilities,” said Michelle Clark, PhD, statistical scientist at RCIGM and the first author of the study. “By informing timely targeted treatments, rapid genome sequencing can improve the outcomes of seriously ill children with genetic diseases.”
Rady Children’s Institutewww.radygenomics.org/category/news/pr/
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:08:03Artificial intelligence to diagnose genetic diseases
Researchers have demonstrated that an optical technique known as Raman spectroscopy can be used to differentiate between benign and cancerous thyroid cells. The new study shows Raman spectroscopy’s potential as a tool to improve the diagnosis of thyroid cancer, which is the ninth most common cancer with more than 50,000 new cases diagnosed in the United States each year.
“Our encouraging results show that Raman spectroscopy could be developed into a new optical modality that can help avoid invasive procedures used to diagnose thyroid cancer by providing biochemical information that isn’t currently accessible,” said James W. Chan from the University of California, Davis, U.S.A. “This could have a major impact in the field of pathology and could lead to new ways to diagnose other diseases.”
A lump — or nodule — in the neck is a common symptom of thyroid cancer. However, most thyroid nodules aren’t cancerous. Ultrasound-guided fine needle aspiration biopsies are typically used to check for cancer by inserting a thin needle into the nodule to obtain cells that are prepared on a microscope slide, stained and analysed by a pathologist. For about 15 to 30 percent of cases, the pathologist cannot determine whether cells acquired from the biopsy are benign or malignant. For these cases, a surgical procedure known as a thyroidectomy is required to remove tissue, which provides more information for a more accurate diagnosis. The researchers turned to Raman spectroscopy as a possible solution because it is a non-invasive technique that requires no sample preparation or staining to determine subtle differences in the molecular composition of complex samples such as cells. “We would like to use Raman spectroscopy to improve the pathologist’s analysis of the cells obtained with fine needle aspiration to reduce the number of thyroidectomies necessary,” said Chan. “This would both minimize surgical complications and reduce healthcare costs.”
For the new study, the researchers used a line-scan Raman microscope that allowed them to rapidly acquire Raman signals from an entire cell volume. This allowed them to more accurately capture the chemical composition of entire cells compared to other approaches that acquire a Raman spectrum from only part of a cell’s volume. Multivariate statistical methods and classification methods were then used to analyse the Raman data and classify the cells in an objective, unbiased manner.
The researchers applied this Raman spectroscopy approach to individual cells isolated from 10 patient thyroid nodules diagnosed as benign or cancerous. The data analysis identified unique spectral differences that could distinguish cancerous cells from benign with 97 percent diagnostic accuracy. They also showed that other subtypes could be identified by their spectral differences.
“These preliminary results are exciting because they involve single cells from human clinical samples, but more work will need to be done to take this from a research project to final clinical use,” said Chan.
The Optical Society (OSA)
https://tinyurl.com/y6hw35z8
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:08:10Raman spectroscopy poised to make thyroid cancer diagnosis less invasive
by Dr Tolga Durak Around the world, organizations are building next-generation research facilities intended to encourage communication, collaboration and creativity. However, these new spaces must overcome a wide range of complex challenges to meet the needs of researchers today and in the future. This article explores five important questions that should be considered in order to build an innovation space that is safe, successful and productive.
Fundamental questions for good design
Research facility design and construction is evolving rapidly, as organizations around the world strive to create work environments that meet the needs of today’s scientists. Whether these new spaces are relatively small-scale makerspaces, large pharmaceutical manufacturing plants, or tightly regulated high-containment laboratories, they are being built to foster communication, collaboration, and innovation, often in ways that depart significantly from the traditional R&D rubric. As a result, every stage of the process – from initial site assessment, architectural design, and construction and continuing all the way through to ongoing maintenance and operation – must be approached with fresh eyes. To get started, design and construction teams must consider the following five fundamental questions. 1. Who is going to work in the facility and what will they need to be successful? Most research projects now span multiple disciplines, and laboratory spaces often need to accommodate the varied needs of biologists, chemists, engineers, physicists and/or others – all working together but with different methods. Research facility design must accommodate each specialty’s unique requirements across a wide spectrum that includes equipment, infrastructure (electrical, ventilation, etc), information technology (IT), workflow and compliance. In addition, designers must factor in flexibility, so workspaces can adapt as the research advances and needs change. 2. What is required for compliance? Navigating regulatory boards and obtaining approvals can be a complex, time-consuming, and expensive process, especially for clinical research facilities. Typically, these structures must be constructed in compliance with Good Laboratory Practice (GLP) regulations, Good Manufacturing Practice (GMP) regulations, and other guidelines and mandates from local, state and federal jurisdictions. In addition, laboratories that research or use infectious agents or other biological hazards must comply with regulations based on the degree of the health-related risk associated with the work being conducted. The four biosafety levels (BSLs) of containment – BSL-1, BSL-2, BSL-3, and BSL-4 – aim to safeguard against the accidental release of pathogenic organisms and other biohazards and may involve airflow systems, containment rooms, sealed container storage, waste management, decontamination procedures, and security capabilities. Clearly, the challenges of compliance need to be tackled early in the design process because meeting all of the requirements can take years, which increases the risk that research priorities change and/or that key staff moves on to other projects. 3. How sustainably can we build it? When people think about sustainable research facility design, they usually focus on power and water consumption. Granted, researchers typically use lots of heat-generating equipment (which then require complementary cooling solutions). Their labs also generally need extensive ventilation, sophisticated sensor networks, uninterrupted power supplies – as well as back-up redundancies for all of these systems. However, in a broader sense, sustainable research facility design also addresses the health and well-being of the workforce. That means air quality, natural light, workflow and productivity considerations, material selection, and all related aesthetics can drive design and construction processes as well. 4. How will the needs of this facility change? Science is constantly evolving, and research priorities will shift over time. Likewise, technology, regulations and workforce needs will change too. Flexibility and adaptability need to be key considerations of every plan, and designers and developers have to strike a balance between short- and long-term needs. In some cases, permanent or portable modular components may be the most efficient and cost-effective options. 5. Is building the best business decision? For some organizations, the best business decision may be to share laboratory space, rather than to build their own. Entering into a partnership, collaboration or lease agreement with an organization that is already operating a facility can expedite research results, reduce costs, ease the burden of meeting compliance requirements and even stimulate innovation. Of course, benefits like those must be weighed against potential disadvantages, such as the lack of customization, loss of control and the risks associated with failure to protect intellectual property.
Summary
Thoughtful consideration of these five key questions will help you create an innovation space that will meet your research needs today and for years to come. As you work through your answers to each one, be sure to solicit input from architects, engineers, builders and others who have the experience and expertise to guide you in the process. Adopting a team approach is essential to building a next-generation innovation space that is that is safe, successful and productive. The author Tolga Durak PhD Environment, Health and Safety Office, Professional Education, MIT, Cambridge, MA 02139, USA E-mail: tdurak@mit.edu
https://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png003wmediahttps://clinlabint.com/wp-content/uploads/sites/2/2020/06/clinlab-logo.png3wmedia2020-08-26 09:31:372021-01-08 11:07:49Enabling innovation: designing research facilities
We may ask you to place cookies on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience and to customise your relationship with our website.
Click on the different sections for more information. You can also change some of your preferences. Please note that blocking some types of cookies may affect your experience on our websites and the services we can provide.
Essential Website Cookies
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to provide the website, refusing them will affect the functioning of our site. You can always block or delete cookies by changing your browser settings and block all cookies on this website forcibly. But this will always ask you to accept/refuse cookies when you visit our site again.
We fully respect if you want to refuse cookies, but to avoid asking you each time again to kindly allow us to store a cookie for that purpose. You are always free to unsubscribe or other cookies to get a better experience. If you refuse cookies, we will delete all cookies set in our domain.
We provide you with a list of cookies stored on your computer in our domain, so that you can check what we have stored. For security reasons, we cannot display or modify cookies from other domains. You can check these in your browser's security settings.
.
Google Analytics Cookies
These cookies collect information that is used in aggregate form to help us understand how our website is used or how effective our marketing campaigns are, or to help us customise our website and application for you to improve your experience.
If you do not want us to track your visit to our site, you can disable this in your browser here:
.
Other external services
We also use various external services such as Google Webfonts, Google Maps and external video providers. Since these providers may collect personal data such as your IP address, you can block them here. Please note that this may significantly reduce the functionality and appearance of our site. Changes will only be effective once you reload the page
Google Webfont Settings:
Google Maps Settings:
Google reCaptcha settings:
Vimeo and Youtube videos embedding:
.
Privacy Beleid
U kunt meer lezen over onze cookies en privacy-instellingen op onze Privacybeleid-pagina.