stago

Coagulation analyser

STA Compact Max®, the new generation Stago analyser, delivers accurate and timely answers to clinicians while helping laboratories to cope with economic and functional challenges by improving efficiency both operationally and environmentally. Its reliability enables this multiparametric system to operate optimally in every situation, including in highly demanding environments in terms of workload and volume testing. Its ergonomic and graphical user interface ensures a seamless integration in the lab. Furthermore, the new additional expert module will provide standardized results with fast turnaround time. Designed for mid-volume throughput laboratories, the instrument is suitable for routine and specialty assays. It offers viscosity-based (mechanical) detection system for clotting assay, chromogenic and immunological testing, extended sample, reagent and disposable loading capacities, true STAT management and high traceability. A wide range of dedicated reagents, quality controls and calibrators is available.
Read more

C289 Immundiagnostik

Vitamin D analysis

Immundiagnostik AG offers a comprehensive test panel for the analysis of vitamin D in research and daily routine. ELISA, HPLC and LC-MS/MS tests enable the reliable determination of the analytes 1,25-(OH)2 vitamin D and 25(OH) vitamin D. The ImmunoTube® LC-MS/MS kit features a superior sample preparation that allows the precise analysis of 1,25-(OH)2 vitamin D3 and D2 in serum or plasma with high specificity and sensitivity and without ion suppression by interfering matrix components. This fast, robust and accurate detection method can be used on commercial high-end instruments. The 25(OH) vitamin D Xpress ELISA accomplishes a convenient and precise status determination in less than three hours. This automatable test quantitatively measures 25(OH) vitamin D in serum, even in small sample volumes. The protocol does not require overnight incubation or cooling, making the assay most suitable for vitamin D status analysis in daily clinical routine.
Read more

C293 Phadia 250 1CMYK

Fully automated fecal calprotectin test

EliA Calprotectin is the first fully automated test for fecal calprotectin helping to differentiate inflammatory bowel diseases (IBD) from irritable bowel syndrome (IBS) and other functional bowel disorders. After stool extraction the test can be processed fully automated on four Phadia® Laboratory Systems (Phadia 100, Phadia 250, Phadia 2500 and Phadia 5000), which meet the needs of laboratories of all sizes. This reduces the workload for the lab personnel, minimizes operational costs and optimizes the workflow. On top of this, EliA Calprotectin shows an excellent performance and provides results of high clinical usefulness. Because of its high sensitivity, the test can be used as a first-line test to rule out IBD, and can help to avoid unnecessary endoscopic procedures, while its high specificity assures a clear identification of IBD patients.
Read more

C265b GlobeScientific GlobeGlassTubes

Borosilicate glass culture tubes

     
Globe Scientific introduces a new line of high quality borosilicate glass culture tubes. The tubes feature well-rounded bottoms and smooth, fire-polished rims. They are neatly packaged in heavy duty boxes of 250 and shrink wrapped to keep them particle free. The boxes are compact and fit into most test tube dispensers.
    
Read more

ELISA for active form of vitamin B12

Current front-line biochemical tests for assessment of Vitamin B12 status suffer from several important limitations including both false positives and false negatives, a wide indeterminate range and measurement of both active and inactive B12. Hematological test results can also be non-specific or misleading. The Active-B12 assay from Axis-Shield provides an innovative and highly accurate method for assessing Vitamin B12 status. The assay measures holotranscobalamin, the bio-active form of the vitamin. Holotranscobalamin represents only 10-30% of circulating B12 but is the only form taken up and utilized by the cells of the body – the Active-B12 assay therefore gives a more accurate assessment of the body’s B12 status. The CE-marked Active-B12 assay is a standard 96-well ELISA with break-apart strips and is supplied with all required reagents, calibrators and controls. The kit is compatible with liquid- handling automated instruments for higher throughput.
Read more

C306 Mindray

Body fluid analysis with hematology instrument

Equipped with the unique SF-Cube technology (laser scatter, fluorescence plus 3D cell analysis), the BC-6800 hematology analyser provides not only the routine parameters such as WBC 5-part diff, RET and NRBC, but also brings more information such as immature granulocyte, blast, atypical lymphocyte, infected RBC (infected by plasmodium parasite), etc. With a processing throughput of 125 tests per hour, it is also suitable for laboratories with large daily sample loads. The BC-6800 now comes with a new feature, body fluid analysis. The instrument can analyse CSF, pleural, peritoneal fluid samples, as well as provide reportable data for RBC, WBC, WBC differential (polymorphonuclear & mononuclear) and a total cell count (TCBF) on these body fluid samples. Moreover, for research use only, the instrument can give additional WBC differential results for neutrophil and eosinophil. HF-BF is an additional, for research use parameter, which represents high fluorescent cells. High fluorescent cells may contain histiocytes, epithelial cells, spleen cells, exfoliated cells, etc. These cells can bring more clinical information for diagnosis.
Read more

C314 Trinity

HSV-2 IgG immunoassay

Trinity Biotech’s Uni-GoldTM HSV-2 Rapid is a single use immunoassay for the qualititative detection of human IgG class antibodies to HSV-2 in human whole blood (venous or capillary) or serum. This product is the newest addition to the Uni-GoldTM range of STD rapid tests. This easy to use test features a 2 step procedure, giving results within 15 minutes. Used as a frontline screening assay, the Uni-GoldTM HSV-2 Rapid complements the company’s confirmatory CaptiaTM HSV Type Specific ELISA assays. The Uni-GoldTM HSV-2 Rapid will ensure communities and STD clinics can detect HSV-2 faster and more accurately at Point-Of-Impact. The HSV-2 test now joins Trinity’s established HIV test as part of the Uni-GoldTM brand of Point-Of-Impact rapid tests.
Read more

seracare logo

Anti-dengue performance panel

The first commercially available Anti-Dengue Mixed Titer Performance Panel has been launched by SeraCare. It is designed to help blood donor collection facilities, diagnostics manufacturers and clinical laboratories evaluate and troubleshoot their anti-dengue virus assays. The new performance panel is derived from undiluted, unpreserved human plasma specimens, with 21 members representing a wide range of reactivity for anti-dengue IgM and IgG antibodies, from negative to strongly positive. Panel members include samples from individuals with recent and past infection by all four dengue viruses (DENV-1 through DENV-4).
Read more

C269 Belart

Fast and accurate colony counting

Even with the advances in automated and robotic colony counters, there still remains a need for accurate, simple to use and lower cost hand-held units. The efficient and accurate handheld Scienceware Colony Counter is ideal for those who only do counting on an irregular basis or only count a few plates at a time and do not wish the expense of investing space and capital in a larger system. Simple to operate, the unit marks, counts and gives an audible and visual alert each time a count is registered on the digital display. The lightweight, comfortable to hold, pen-style design reduces the likelihood of error, combining all aspects of counting into one motion. Error is further reduced by the ability to count both up and down to verify sample counts. Able to store up to 35 sample counts in its memory, it can also display the sum total of all colonies counted. The display has a backlight for easy viewing in low light conditions, the audible alert can be turned off if desired, and the counting function can be locked to prevent error during breaks between counting. Long-life, red and black felt-tip markers, a protective storage case and a 3V lithium battery are included. A complete counting system that includes the colony counter, a magnifier, light box, AC adapter, and counting grid is also available.
Read more

C301 DiagnosticaStago

HIT diagnostic test

Patients with Heparin Induced Thrombocytopenia (HIT) have a very high thrombosis risk. They require alternative anticoagulant treatments which increase the bleeding risk. In the absence of a rapid and reliable laboratory assay, many clinicians simply replace heparin based on clinical suspicion only. However, only about 10% of HIT suspicions are actually confirmed by appropriate tests. Current immunoassays can rule out HIT but have limitations, especially a high number of false positive tests, long time to result, complex handling, and reagent wastage. The STic Expert® HIT kits match all laboratory requirements, including reliability (100% Negative Predictive Value), which rules out HIT when combined with the pretest clinical score, and 93% specificity, which reduces false positive results and the number of confirmatory tests required. Results are available in 10 minutes. Easy and ready to use, the unitary test is available 24/7 STAT compliant for laboratories of all sizes. It reduces the cost of HIT outsourcing and eliminates the need for extra equipment. Two packaging sizes are available, 5 tests per kit and 20 tests per kit, with individual tests in blister packs.
Read more