Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
November 2025
The leading international magazine for Clinical laboratory Equipment for everyone in the Vitro diagnostics
Prins Hendrikstraat 1
5611HH Eindhoven
The Netherlands
info@clinlabint.com
PanGlobal Media is not responsible for any error or omission that might occur in the electronic display of product or company data.
This site uses cookies. By continuing to browse the site, you are agreeing to our use of cookies.
Accept settingsHide notification onlyCookie settingsWe may ask you to place cookies on your device. We use cookies to let us know when you visit our websites, how you interact with us, to enrich your user experience and to customise your relationship with our website.
Click on the different sections for more information. You can also change some of your preferences. Please note that blocking some types of cookies may affect your experience on our websites and the services we can provide.
These cookies are strictly necessary to provide you with services available through our website and to use some of its features.
Because these cookies are strictly necessary to provide the website, refusing them will affect the functioning of our site. You can always block or delete cookies by changing your browser settings and block all cookies on this website forcibly. But this will always ask you to accept/refuse cookies when you visit our site again.
We fully respect if you want to refuse cookies, but to avoid asking you each time again to kindly allow us to store a cookie for that purpose. You are always free to unsubscribe or other cookies to get a better experience. If you refuse cookies, we will delete all cookies set in our domain.
We provide you with a list of cookies stored on your computer in our domain, so that you can check what we have stored. For security reasons, we cannot display or modify cookies from other domains. You can check these in your browser's security settings.
.These cookies collect information that is used in aggregate form to help us understand how our website is used or how effective our marketing campaigns are, or to help us customise our website and application for you to improve your experience.
If you do not want us to track your visit to our site, you can disable this in your browser here:
.
We also use various external services such as Google Webfonts, Google Maps and external video providers. Since these providers may collect personal data such as your IP address, you can block them here. Please note that this may significantly reduce the functionality and appearance of our site. Changes will only be effective once you reload the page
Google Webfont Settings:
Google Maps Settings:
Google reCaptcha settings:
Vimeo and Youtube videos embedding:
.U kunt meer lezen over onze cookies en privacy-instellingen op onze Privacybeleid-pagina.
Privacy policy
ELISA for bone metabolism disorders
, /in Product News /by 3wmediaAnalysis of 25-OH vitamin D, intact parathyroid hormone and calcitonin is useful in the diagnosis of bone metabolism disorders. This triad of parameters can be determined quickly, accurately and cost-effectively using specialised ELISA test systems from Euroimmun. The intact-parathyroid hormone (iPTH) and calcitonin ELISAs are new sandwich assays based on specific capture antibodies. The substance under investigation is bound into a complex by the antibodies and then detected by means of a colour reaction. iPTH determination represents the most important serological test for diagnosis of primary hyperparathyroidism and also supports the clarification of secondary and tertiary forms of the disease. Calcitonin analysis is generally employed for clarifying scintigraphically cold thyroid nodules. A high serum calcitonin level is found in medullary thyroid carcinoma (C-cell carcinoma), whereby 20 to 30% of patients with this cancer exhibit hyperparathyroidism. Hypovitaminosis D is linked to bone atrophy as well as numerous other conditions such as autoimmune diseases, infections, cancers, cardiovascular disease and mental disorders. Patients are generally treated with supplementation, but must be monitored regularly due to widely differing responses. The Euroimmun ELISA measures 25-OH vitamin D, which of all the vitamin D metabolites in the blood best reflects the current storage status. The assay employs an antibody that is equally specific for both D2 and D3 forms of the vitamin, which is critical since either D2 or D3 may be used for treatment. The ELISA shows a high correlation with the LC-MS and HPLC reference methods. The 25-OH Vitamin D, iPTH and calcitonin ELISAs are easy to perform and include ready-to-use, colour-coded reagents and break-off wells for added convenience. The test systems are compatible with all commercial washer and reader systems and can, moreover, be
processed fully automatically on the Euroimmun Analyser.
Read more
Diagnostics Solutions
, /in Product News /by 3wmediaAvantor™ Performance Materials is committed to advancing the quality and effectiveness of histology and cytology laboratory processes for diagnostic applications by providing a comprehensive line of J.T.Baker® brand alcohols, solvents, fixatives, stains, mounting media, and xylene alternatives.
Our Histology and Cytology Reagents are produced using state-of-the-art manufacturing techniques at facilities certified for excellence in quality control, customers can count on Avantor’s the histology and cytology products from J.T.Baker® to deliver efficient, reliable results, time after time.
Visit: www.avantormaterials.com/Diagnostics-Global for more information or send us an email: avantor.emea@avantormaterials.com
Read more
Biohit Helicobacter pylori UFT300 quick test
, /in Product News /by 3wmediaBiohit is introducing an improved liquid method for H. pylori detection from biopsy samples, the Helicobacter pylori UFT300 quick test. The detection is based on the detection of bacterial urease activity in gastric biopsy specimens. A gastric mucosa colonized by H. pylori is invariably inflamed, and can lead to atrophic gastritis, which has been linked with peptic ulcer and gastric cancer, two of the most important diseases of upper gastrointestinal tract. The quick test is easy to storage and perform and results are ready in a few minutes enabling diagnosis and reporting at the point of gastroscopy.
Read more
α1-microglobulin reagent
, /in Product News /by 3wmediaA new α1-microglobulin test has been developed for the determination of this excellent marker for the evaluation of renal tubular function. α1-microglobulin is also elevated in heavy metal poisoning, following renal colic, decreased glomerular filtration and renal disease associated with diabetes. After its secretion into the blood, α1-microglobulin is found in free form and in a wide variety of complexes. Only the free form of α1-microglobulin is filtered through the glomerulus and then reabsorbed by the proximal tubule of the nephron where it is degraded. In conditions with impaired tubular function, α1-microglobulin reabsorption decreases and its concentration in urine increases. This turbidimetry reagent is available in Manual and Automated Systems Reagents presentations.
Read more
Methylmalonic acid kit for vitamin B12 status determination
, /in Product News /by 3wmediaNow available is the MassChrom LC-MS/ MS kit for the analysis of methylmalonic acid (MMA) in plasma, serum and urine. Methylmalonic acid is an intermediate of amino acid metabolism and is regarded as an early and sensitive biomarker of vitamin B12. A deficiency leads to increased levels of MMA in plasma, serum and urine. The use of special Clean-up Tubes enables a quick sample preparation that removes interfering compounds effectively. False-positive test results are prevented by chromatographic separation of the isobaric compound succinic acid. Precision of results is ensured with stable isotope-labelled internal standards as well as the matrix-adapted 3PLUS1 Multilevel Plasma and Urine Calibrators.
Read more
Line of -30˚C freezers
, /in Product News /by 3wmediaA brand new line of -30˚C biomedical freezers provides cost-efficient and secure sample storage across a wide range of applications. A combination of technological advances reduces energy consumption and improves temperature stability, delivering the effective, reliable environmental control needed when storing valuable materials such as vaccines, diagnostic samples, enzymes, culture media and reagents. In conventional freezers, single speed compressors maintain the freezer temperatures by cycling on and off. Panasonic’s new biomedical freezers incorporate inverter compressors which can run at varying speeds to optimize cooling performance under different conditions and ensure highly reliable, efficient operation. This is the first time that such technology has ever been employed in -30˚C freezers. The use of inverter compressors significantly improves the temperature uniformity of the freezer and reduces energy consumption for decreased environmental impact and lower running costs. Natural hydrocarbon (HC) refrigerants also contribute to the low carbon footprint of these new freezers. The -30˚C biomedical freezers feature intuitive microprocessor control with an easy-to-read digital display, which delivers comprehensive set point, alarm, monitoring and diagnostic functions to track system conditions and alert users in the unlikely event of temperature abnormalities.
Read more
Enteric adenovirus test
, /in Product News /by 3wmediaAdenoviruses are non-enveloped viruses containing a double stranded DNA genome. They infect humans with 57 distinct adenovirus serotypes distributed in 6 groups from A to F and cause a wide range of illnesses, from mild respiratory infections to life-threatening multi-organ diseases in people with a weakened immune system. Most infections with adenovirus result in infections of the upper respiratory tract, conjunctivitis, ear infections or croup. But types 40 and 41 adenoviruses (group F) are mainly responsible for gastroenteritis. They infect mature enterocytes in the small intestine primarily in young children during the winter season. Some people with group F adenovirus gastroenteritis may shed the virus in their stools for months after getting rid of the symptoms. Prevalence of adenovirus 40/41 is known to be between 2 and 6 % and is the fourth cause of viral diarrhea. A specific diagnostic test like the GastroVir test developed by Coris BioConcept makes it possible to discriminate between respiratory and enteric adenovirus, since excretion could be concomitant.
Read more
sTNFr1 test kit
, /in Product News /by 3wmediaA new test kit for Soluble Tumour Necrosis Factor receptor 1 (sTNFr1) is available for sale. sTNFr1 identifies diabetic patients at high risk of End Stage Renal Disease (ESRD) up to 10 years in advance. Based on a standard ELISA, the test detects circulating levels of sTNFr1 in just a few hours. Early diagnosis of ESRD leads to improved patient outcomes and reduced healthcare costs. The ELISA kit was developed in conjunction with the Joslin Diabetes Center in Boston, USA. 20 years after the onset of overt nephropathy, approximately 20% of diabetic patients will have progressed to ESRD. The sTNFr1 assay will lead to improvements in the way ESRD is detected and managed.
Read more
Multiplex PCR test
, /in Product News /by 3wmediaThe FilmArray is a FDA-cleared multiplex PCR test that integrates sample preparation, amplification, detection and analysis all into one automated system. It requires just two minutes of hands-on-time and its turnaround time is just about an hour, giving you faster results which may lead to better patient care.
The FilmArray now has two FDA-cleared panels – the Respiratory (RP) Panel and the Blood Culture Identification (BCID) Panel. Together, these two panels test for more than a hundred species of pathogens. Thus, FilmArray is not only the fastest way to better results; it’s the fastest way to more results.
Phone: 800-735-6544
Website: www.FilmArray.com
Read more
Hemoglobin A1c reagent
, /in Product News /by 3wmediaNow introduced is a two-component immunoturbidimetric reagent for the determination of hemoglobin A1c on general chemistry analysers. The methodology uses a highly specific monoclonal antibody to hemoglobin A1c to generate increased turbidity in the presence of hemoglobin A1c. With the single R2 component stabilized, mixing two separate R2 components is no longer necessary. This single R2 component provides the consumer with unsurpassed ease of use. Automated hemolysis can be performed on many different chemistry analyzers, providing a totally automated test system. The simple competitive binding principle used in this hemoglobin A1c method provides direct determination of hemoglobin A1c. This eliminates the need to perform a total hemoglobin assay, providing greater accuracy and precision by removing the additive error from performing two assays to achieve a single result. The method can be applied to most general chemistry analysers. This eliminates the need for a dedicated hemoglobin A1c analyser, reducing capital expenditures and labour costs while increasing efficiency and productivity. These hemoglobin A1c reagents are liquid-stable and have been shown to be accurate and precise. Pointe Scientific’s hemoglobin A1c calibrators are referenced to IFCC materials and are also NGSP certified. Hemoglobin A1c controls are also available for use with the new hemoglobin A1c reagent.
Read more