C374 Biosystems pic calcium CPC

Calcium-Cresolphtalein reagent

Calcium in the sample (serum, plasma or urine) reacts with o-cresolphtalein complexone (o-CPC) forming a coloured complex that can be measured by spectrophotometry. BioSystems covers different calcium CPC presentation kits adjusted to different analysers as well as manual presentations which include an aqueous primary standard. Despite this, it is recommended to calibrate using a biochemistry calibrator, bovine-(18011) or human-(18044) based. The calcium concentration values for all serum reference materials provided for this new method are the same as for the MTB method.

Read more

C376 Sclavo IMG 2425

Kits for urinary protein testing

A complete range of kits for the testing of urinary proteins is available. Such tests are particularly useful from a diagnostic viewpoint, providing important information for the diagnosis of renal diseases, monitoring and differential analysis of proteinurias. All reagents are latex-based, ready-to-use and validated according to the international CLSI protocols. Within the range, urinary-Transferrin, urinary-Albumin (micro-albuminuria), and urinary-IgG, are of paramount importance. Albuminuria is one of the most important markers for damages to the endothelium. Pathological levels of urinary albumin (micro-albuminuria) are present in diabetes, hypertension, and during the early stages of preeclampsia. Transferrin and albumin together are pathognomonic of selective glomerular proteinuria. If the IgG levels rise the glomerular proteinuria becomes non selective. The accuracy guaranteed by the method allows correct calculation of the Cameron index (ratio between IgG clearance and transferrin clearance). The urinary proteins kits are available as both turbidimetry and nephelometry. The dedicated product lines include calibrators and controls whose assigned values are in accordance with International Scientific Committee’s guidelines. All urine testing products from Sclavo are available in specific formats and packaging developed for all Sclavo Systems (Sclavo Palio, Dirui, Konelab), Sclavo EasyNeph (nephelometry), in addition to the multi-purpose format. Along with specific proteins kits, the company offers a dedicated kit for testing total urinary proteins, highly sensitive to both tubular proteins, as well as Bence-Jones proteinuria, ensuring reliable and accurate results.

Read more

C375 Biohit pic

Colorectal cancer screening test

Biohit is introducing the new ColonView Hb and Hb/ Hp tests, which are intended for simple detection of fecal occult blood in stool samples. The detection of blood is based on sensitive and specific immunochemical detection of human hemoglobin or hemoglobin/haptoglobin complex. The principal application of the tests is to screen for lower gastrointestinal pathologies, such as colorectal cancers and large adenomas that bleed. The quick and simple, one-step lateral flow tests require no dietary restrictions and give results in only 15 minutes.

Read more

C380 Hemosure pic

Immunochemical fecal occult blood test

Various Fecal occult blood tests (FOBTs) are available, however, many have a high rate of inaccuracies and false positives.  The Hemosure iFOBT (FIT) -fecal immunochemical test- doesn’t require drug or diet restrictions, only one test is needed and it has a higher patient compliance rate. A rapid, convenient and odourless qualitative, sandwich dye conjugate immunoassay, the test employs a unique combination of monoclonal and polyclonal antibodies to selectively identify elevated levels of human hemoglobin as low as 50 ng / mL in five minutes. It is a useful aid in the diagnosis of gastrointestinal (GI) bleeding in a number of GI disorders, e.g. diverticulitis, colitis, polyps, and colorectal cancer. The immunochemical test is specific to human hemoglobin and reduces false positives while offering the correct level of specificity and sensitivity for accurate reading.

Read more

Liquid chemistry controls

Containing 100 analytes all within one vial, Acusera Liquid Assayed Chemistry Premium and Premium Plus drastically reduce the number of individual controls a laboratory needs to run, whilst ensuring highly accurate results. The controls contain a unique combination of proteins, lipids, immunoassays, cardiac markers, therapeutic drugs and routine chemistry analytes. High levels of CRP and key proteins eliminate the need for multiple controls.  The controls are assayed, with clinically significant values provided for a range of analysers at key decision points. Available in three concentration levels covering the full clinical range, the controls are liquid for ease of use and highly stable when stored at -20 to -70°C with open vial stability of up to 7 days at +2-8°C. Manufactured using high quality human-based serum, ensuring performance that closely mirrors patient samples, these true third party controls enable unbiased and independent assessment of analytical performance.

Read more

C377 Coris image

Human African Trypanosomiasis test

Human African Trypanosomiasis (HAT) or sleeping sickness is a life threatening neglected tropical infection affecting rural population in sub-Saharan Africa. The disease causes severe neurological disorders often leading to death if not treated. Since years, HAT control has been facilitated by the Card Agglutination Test for Trypanosomiasis (CATT/T.b.gambiense), which is particularly suited for large scale screening. But now, with the steadily decreasing prevalence of HAT, specificity becomes a critical parameter. Furthermore, the target population lives in precarious conditions (without electricity) and this test must be robust enough to be carried out in very difficult conditions. A new diagnostic test stable at ambient temperature, cheap and that can be performed with minimal training is the best solution.  To fulfil all these requirements, Coris BioConcept has developed the “HAT Sero K-SeT”, which has been successfully validated in the DR of Congo (specificity of 98,6 % ; sensitivity of 98,5 % ; n=493).

Read more

C358 Tosoh D Dimer AIA Pack Tray 2942

D-Dimer automated Immunoassay

D-Dimer is a critical test to rule out the presence of a thrombus, especially in patients in suspicion of deep vein thrombosis (DVT), pulmonary embolism (PE) or strokes. Other applications are situated in the diagnosis of hypercoagulation and disseminated intravascular coagulation (DIC). The ST AIA-Pack D-Dimer assay uses the Tosoh AIA-Pack single test technology: all specific reagents to perform one test are contained in one and the same cup (one cup = one test), making it a most economical way to perform immunoassays. The D-Dimer result becomes available in less than 20 minutes after the start of the test and runs on all Tosoh Automated Immunoassay Analysers (AIA-360, AIA-900 series, AIA-2000). The test meets all standards for the routine and emergency clinical diagnosis.

Read more

C381 Eurogentec

Quantitative PCR reagents

Takyon is the new Eurogentec qPCR line developed to give access to a new level of speed in qPCR applications. Its name is inspired by the faster than light particle (Tachyon). Emerging from the combination of an optimized reaction buffer and a new efficient enzyme, Takyon for SYBR and Probe Assays ensure sensitivity and fast delivery of accurate and reproducible results. With Takyon qPCR Kits, amplification is achieved with a very short extension time of 15 seconds, enabling clear detection of low copy targets also on difficult templates together with excellent reproducibility across the different runs of the same template. Available as MasterMixes and Core Kits, Takyon kits possess universal capabilities. Combined with the company’s inert Blue Dye, it enhances visualization and reveals to the naked eye dispensing errors that may occur during assay set-up.

Read more

C371 Beckman Allegra X 5 centrifuge

Benchtop centrifuge

The Allegra X-5 air-cooled benchtop centrifuge from Beckman Coulter Life Sciences is designed specifically for clinical sample preparation. As the latest member of the Allegra suite of benchtop centrifuges, the unit offers performance, reliability and endurance under exacting circumstances. Bundled packages, which include swinging bucket rotors and common adapters, enable fast and convenient setup, are offered for a range of clinical sample prep applications, and make it easy to order these energy efficient units. Throughput and productivity are enhanced through seamless integration with the Beckman Coulter Automate 2500 family of sample processing systems.  Furthermore, the company’s UniCel DxC and UniCel DxI sample racks can be spun directly in the centrifuge, eliminating transfer steps. A small footprint allows the unit to fit comfortably on the benchtop, while still providing capacity for up to 140 blood collection tubes.  Maximum speed of 4700 rpm and centrifugal force of up to 4470 x g shortens run times.

Read more

C373 Euroimmun pic

ELISA for bone metabolism disorders

Analysis of 25-OH vitamin D, intact parathyroid hormone and calcitonin is useful in the diagnosis of bone metabolism disorders. This triad of parameters can be determined quickly, accurately and cost-effectively using specialised ELISA test systems from Euroimmun. The intact-parathyroid hormone (iPTH) and calcitonin ELISAs are new sandwich assays based on specific capture antibodies. The substance under investigation is bound into a complex by the antibodies and then detected by means of a colour reaction. iPTH determination represents the most important serological test for diagnosis of primary hyperparathyroidism and also supports the clarification of secondary and tertiary forms of the disease. Calcitonin analysis is generally employed for clarifying scintigraphically cold thyroid nodules. A high serum calcitonin level is found in medullary thyroid carcinoma (C-cell carcinoma), whereby 20 to 30% of patients with this cancer exhibit hyperparathyroidism. Hypovitaminosis D is linked to bone atrophy as well as numerous other conditions such as autoimmune diseases, infections, cancers, cardiovascular disease and mental disorders. Patients are generally treated with supplementation, but must be monitored regularly due to widely differing responses. The Euroimmun ELISA measures 25-OH vitamin D, which of all the vitamin D metabolites in the blood best reflects the current storage status. The assay employs an antibody that is equally specific for both D2 and D3 forms of the vitamin, which is critical since either D2 or D3 may be used for treatment. The ELISA shows a high correlation with the LC-MS and HPLC reference methods. The 25-OH Vitamin D, iPTH and calcitonin ELISAs are easy to perform and include ready-to-use, colour-coded reagents and break-off wells for added convenience. The test systems are compatible with all commercial washer and reader systems and can, moreover, be
 processed fully automatically on the Euroimmun Analyser.

Read more